N61e V1.0 or Higher INTRODUCTION Thank you for choice of the DUALSKY automatic charger, N61e, which has outstanding performance and reliable technology for many different battery types. N61e Packing SERVICE If you have any questions, please consult the instructions first.
N61e V1.0 or Higher PRECAUTIONS N61e is simple to use, but the safe operation requires some knowledge of batteries and chargers. Mishandling batteries or chargers can be dangerous, as it involves a risk of the batteries exploding and catching fire or charger’s permanent damage.
N61e V1.0 or Higher The N61e provides convenient and professional charging functions, which are based on different batteries capacity and charging capabilities: FAST/ STD/ SLOW/ STORAGE. Instead of tedious manual setting, the operating current is fixed at a variant charge rate (C). In the MANU function, you can adjust the current from -3A to +10 A.
‘V ×.×’. At this time the cooling fan will run for a short time and both signal lights will flash on and go off. In this case you can check out whether they are operating properly. The system will then go to the most recently-used memory. At the initial use, it will go to the Top Menu by default.
N61e V1.0 or Higher The Top Menu lists eleven memory positions, ten for Battery Memories (Batt.A, B, …J) and one for SYSTEM PARAMETER. Except for empty memories which are indicated by an asterisk, Battery Memories show their major information in-line on the LCD, including the memory number, battery type and quantity of cells in series, capacity.
In any Batt.M, rotate the dial to page up and down and you can skim the battery parameters. Press the dial to start editing parameters. The editing parameter will flash. Then rotate the dial to find your desired value. Re-press to confirm it. Except for the last term, the next parameter will be allowed to be edited at once.
Page 11
19.8V Li-FePO4 Par3. Capacity Capacity is a very important parameter for N61e. This parameter will work on the operating control. It’s mostly obvious that it determines the charge current at FAST/ STD/ SLOW/STG function. The charge rate is fixed. But the actual value is determined by the capacity you set.
Page 12
You can define the max charging capacity to avoiding overcharging. This percentage value relates to the set capacity. The range is INH, 1 … 120% for lithium. ‘INH’ means N61e will ignore this stop condition. Par7. RESET BATT. For avoiding the mis-operation when you RESET BATT.
‘b’ indicates which cells are being balanced. Figure 2 BALANCER 4000 3995 3990 After powering on the N61e, no matter whether a battery has been connected to the output, the balancer will auto run at once as Page.6(Par11) N61e Balance Port→...
Recommended charging temperature: NiCd 15°C~45 °C, Ni-MH 0°C~ 40 °C N61e tries to detect the precise static △V(delta V) for the best possible full charge. But the -△V is impacted by many factors, likely the charging rate, surrounding temperature, as well as the batteries service time. It’s better to terminate the charge by a series of conditions.
Page 15
Optional Function & Operating Current For NiMH & NiCd type, FAST/STD/SLOW/STG/CYC/MANU functions are available. The detail refers to Table.N61e Operating Function Option. At CYC function, you can program the cycle counts, the first operating current and the next in turn on the second line of the screen.
You can define the max charging capacity to avoiding overcharging. This percentage value relates to the set battery capacity. The range is INH, 1 … 150% for lithium. ‘INH’ means N61e will ignore this stop condition. Par11. RESET BATT Par12. HISTORY Par13.
CAP. MAX You can define the max charging capacity to avoiding overcharging. This percentage value relates to the set battery capacity. The range is INH, 1 … 120% for lithium. ‘INH’ means N61e will ignore this stop condition. Par7. RESET BATT Par8.
N61e V1.0 or Higher For lithium or Lead-Acid type, the charge mode is CCCV. During working at CV, there are 3 icons indicating the state of charge of the pack. The first state shows ‘A’, just CV processed recently. The second shows ‘b’, as operating currents decrease further, and the batteries have been charged more than 90% of capacity.
N61e V1.0 or Higher Three steps are needed to create a new battery memory. First, program the battery type. Second is the capacity. And third, the cells number (S). Then the charger will complete the batteries parameter and make up a new battery memory.
Confirm whether a battery is connected to the output in reverse. Battery Disconnected! Confirm whether a battery has connected with the output properly. Hardware Error! It happened on leakage or surge current. N61e Power on again. And try to run 18/23...
Page 21
N61e V1.0 or Higher the battery memory again. If it always alarm contact DUALSKY Services for further details. Cells Number Error! Confirm the batteries cells setting Battery Overvoltage! Confirm the batteries cells setting or the batteries voltage. Battery Undervoltage! Confirm the batteries cells setting or the batteries voltage.
Page 22
N61e V1.0 or Higher CONTENTS SET CONTENTS Part Description N61e A automatic Charger A set of alligator clips for input connections to female banana jacks A piece of Fuse:20A A set of connecting leads with 4mm gold contact connectors A Balancing adapter lead N6.BA234...