Setting the Scan Range

SCAN LIMIT:
ALL 200 512 - 698
The scan range menu sets the frequency range that the URX50 will scan. Pressing the CH UP and CH DOWN keys
will cycle through the scanning options.
Available Scan Ranges
All 200 - All frequencies from 512.0MHz through 698.0MHz will be scanned.
LO 100 - Corresponds to the frequency range of 3.5 transmitters, when selected the URX50 will scan all
frequencies from 512.0MHz through 614.0MHz.
HI 100 - Corresponds to the frequency range of 3.6 transmitters, when selected the URX50 will scan all
frequencies from 596.0 through 698.0MHz.
BLK (20 -26) - Allows the URX50 to scan a specific block (Blocks 20-26).
Block 20 - 518-542 MHz
Block 21 - 536-572 MHz
Block 22 - 560-590 MHz
Block 23 - 590-614MHz (block 23 needs to be enabled)
Block 24 - 614-644 MHz
Block 25 - 638-668 MHz
Block 26 - 662-692 MHz