  • Page 1 Sentinel SLGR 1400X AlorAir Solutions INC. 2048E.FrancisStOntarioCA91761 Add: Tel: 888-990-7469 E-mail: sales@alorair.com...
  • Page 3: Table Of Contents

    TableofContents ..........ImportantNotes ........WarrantyRegistration ..........Specifications ..........HowitWorks ............Installation ..........KeyFunctions ..........IndicatorLights ..........RemoteControl ........OperatingInstructions ..........UnitDiagram ........... Maintenance ........DehumidifierStorage ..........Troubleshooting ............ SpareParts ........WarrantyInformation...
  • Page 4: Importantnotes

    This information is necessary for seeking assistance in the future and can be found on the data label on the side of the unit. Model Number: AlorAir Sentinel SLGR 1400X SerialNumber:______________DateofPurchase:_____________ For additional questions concerning your dehumidifier, contact your...
  • Page 5: Specifications

    ETL Listed: Yes How It Works AlorAir dehumidifiers use an integrated humidistat to monitor theconditioned space. When the relative humidity goes above the selected setpoint, the dehumidifier will energize. Air is then drawn across an evaporator coil, which is cooler than the dew point of air. This means moisture will condense out of the air.
  • Page 6: Keyfunctions

    Key Functions 1.PowerKey illuminate green (solid or flashing depending on mode). ·Press the power button a second time and you will hear one beep as the machine shuts down. Note that there is a 1-minute fan delay. 2.ArrowButtons ·Usetheupanddownarrowbuttonstosetthedesiredhumiditysetpointonthedisplay screen. ·The setpoint can be any number between 36%-90%.
  • Page 7: Indicatorlights

    Indicator Lights 1. Humidity Display Screen ·The display screen has two functions: 1. When the unit is powered on, it shows the humidity of the space 2. When setting the desired humidity level, the screen will show the set point. After a brief delay, it will revert to current humidity of the space.
  • Page 8: Remotecontrol

    Remote Control Instructions AlorAir Dehumidifiers can be controlled using an optional remote accessory. The remote connects to your dehumidifier via a 25’ CAT 5 cable, with the integrated sensor giving you multiple options for monitoring surrounding conditions. Example #1- Install the dehumidifier in the laundry room and duct it into the living room.
  • Page 9: Operatinginstructions

    1 minute after the unit has shut off. DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP. ·The AlorAir Sentinel SLGR 1400X has an integrated condensate pump. During normal operation, the 1400X will automatically drain as required.
  • Page 10: Unitdiagram

    Unit Diagram MERV-10 Filter MERV-1 Filter Side Panel Control Panel Remote Control Drain Hose Connection Power Cord...
  • Page 11: Maintenance

    Pump Maintenance Your AlorAir Sentinel SLGR 1400X is equipped with an integral condensate pump designed to pump water from the dehumidifier out to the desired drain. The pump requires routine maintenance that is not covered by the warranty.
  • Page 12 Removing the Pump 1. Remove the 7 screws on the side panel and set panel aside. 2. Remove the screw holding the pump in place. 3. Undo the 3 pump electrical quick connects and 1 drain quick connect. 4. Insert a flat head screwdriver into the notch on the side of the pump.
  • Page 13: Dehumidifierstorage

    Dehumidifier Storage If the unit will be stored for an extended period of time, complete the following steps: 1. Turn o ffthe unit and allow it to dry. 2. Complete steps 1-3 in Advanced Pump Cleaning to clean out the pump reservoir.
  • Page 14: Troubleshooting

    Troubleshooting Symptom Cause Solution Verifythatboth ends of the power cord are Poor Connection plugged in Diaplay is Blank Power Outage Reset power Cleanthefilter FilterisDirty NoAirFlow AirInletorOutletisBlocked. Cleartheblockage Check to ensure that the sensor wire is Humidity Sensor or connected at both ends, if no issues are TroubleCode: Communication Error visible, the sensor may be faulty.
  • Page 15: Spareparts

    Spare Parts Remote Control Fan Components Remote Control Assembly N-802 AlorAir Fan Motor (includes W-101 and W-100 AlorAir Complete Fan W-102) N-804 Assembly W-101 AlorAir Remote Control Fan Capacitor N-117 AlorAir Remote Control W-102 Cable Filters + External Components Display/Control...
  • Page 16: Warrantyinformation

    5. If the unit can no longer be fixed, and it is in the warranty period and determined to be valid claim, we will ship the customer a new unit within the same year warranty from the date of replacement. 6. After parts are repaired or replaced by AlorAir, the original warranty period continues to apply until it meets its d eadline.