This information is necessary for seeking assistance in the future and can be found on the data label on the side of the unit. Model Number: ALORAIR Sentinel HDi120 SerialNumber:______________DateofPurchase:_____________ For additional questions concerning your dehumidifier, contact your local installer or call AlorAir at 888-990-7469...
The inlet needs a minimum of 6' clearance and the discharge requires a minimum of 36” clearance. • For the best air diffusion, install the unit so that a side panel faces the wall. • Alorair dehumidifiers are only intended for operation when the unit is upright and level with the feet on the ground.
Installation 1. Place dehumidifier on a level surface. • Do not place unit directly on vapor barrier. For example, use blocks or pavers to create a level surface. • If unit has been turned or flipped so that the compressor did not remain upright, place the unit on a level surface and wait a minimum of 2 hours before proceeding.
• The continuous light will illuminate green and the display will show “CO”. •To switch back to normal humidistat operation, use the arrow keys to move the setpoint above 36%. 4. Manual Drain Button •If you need to store or move your dehumidifier, press the “Drain” button to remove water from the integral pump’s reservoir.
Remote Control Instructions AlorAir Dehumidifiers can be controlled using an optional remote accessory. The remote connects to your dehumidifier via a 25’ CAT 5 cable, with the integrated sensor giving you multiple options for monitoring surrounding conditions. Example #1- Install the dehumidifier in the laundry room and duct it into the living room.
DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP. 4. Water Drainage •The AlorAir Sentinel HDi120 has an integrated condensate pump. During normal operation, the HDi120 will automatically drain as required. •If you would like to store or move your unit, press the drain button to drain water from the pump reservoir.
Unit Diagram Control Panel Handle Side Panel Pre-filter FrontView Remote Control Discharge Grille Drain Hose Connection Power Cord Ventilation FanPort Auxiliary (Optional) Terminals BackView...
Pump Maintenance Your AlorAir Sentinel HDi120 is equipped with an integral condensate pump designed to pump water from the dehumidifier out to the desired drain. The pump requires routine maintenance that is not covered by the warranty.
Page 11
Removing the Pump 1. Remove the 9 screws on the side panel and set panel aside. 2. Remove the screw holding the pump in place. 3. Undo the 3 pump electrical quick connects and 1 drain quick connect. 4. Insert a flat head screwdriver into the notch on the side of the pump.
Dehumidifier Storage If the unit will be stored for an extended period of time, complete the following steps: 1. Turn off the unit and allow it to dry. 2. Complete steps 1-3 in Advanced Pump Cleaning to clean out the pump reservoir.
Troubleshooting Symptom Cause Solution Verifythatboth ends of the power cord are Poor Connection plugged in Diaplay is Blank Power Outage Reset power FilterisDirty Cleanthefilter NoAirFlow AirInletorOutletisBlocked. Cleartheblockage Check to ensure that the sensor wire is Humidity Sensor or connected at both ends, if no issues are TroubleCode: Communication Error visible, the sensor may be faulty.