8.1,
ALARMS.
STEAM TIME OUT ALARM
· After starting the resistance and reaching the water overheating
temperature, deliver the steam within 120 seconds.
· Once the time out time has elapsed, the resistance indicated by
the intervention of the buzzer is deactivated, the error code (E01)
appears on the display and the key (1) lights up red.
· Remove the alarm by pressing the key (1), the only operation that
can be performed.
HOT W ATER TIME OUT ALARM
· After starting the pump and reaching the water heating temperature,
deliver the hot water within 120 seconds.
· After the time out time, the pump is deactivated, indicated by the
buzzer, the error code (E02) appears on the display and the key
(2) lights up red.
· Remove the alarm by pressing the key (3), the only operation that
can be performed.
PROBE MALFUNCTION ALARM
· In case of probe malfunction, the code (E03) appears on the
display.
· It will no longer be possible to carry out any operation and the
keys are disabled, turn off the machine and contact the Service
Centre.