5.1,
W ATER SUPPLY.
This model does not require connection to the water supply, the water for brewing coffee,
suitably softened, it is taken from the rear tank.
5.2,
ELECTRICAL CONNECTION.
The machine is connected to the mains with the power cord of equipment, with plug.
Check that all switches are in the "OFF" position.
· It is absolutely mandatory connection of grounding, and the correspondence of the system
with applicable regulations in the country of installation.
· Check the power supply (see data plate); It must match the local power supply.
· You may not use extension cords and jumper cables; the workplace is inevitably exposed to
water and humidity that affect the conditions of isolation system.
· If the power cord is damaged, it must be replaced with one having the same characteristics,
only by the installer / maintainer authorized and specialized. Failure to do so may cause
damage and result in electric shock.