Basic settings ............................................................................................................ 43
13) R9001 (A),C9001 (B),R9004 (C),C9014 (D),R9010 (E): Y-Final Amplifier
17) Calibration Menue. ............................................................................................... 51
18) CH I Amplifier ...................................................................................................... 51
19) CH II Amplifier. .................................................................................................... 51
20) Trigger Amplifier. .................................................................................................. 51
23) R4841: X-Gain x1. ................................................................................................ 51
27) R9008: Y-Gain CH I. ............................................................................................. 55
28) Y-Gain CH II. ........................................................................................................ 55
30) R4839: XY-Gain .................................................................................................... 55
32) Trigger Filter Check. ............................................................................................. 56
35) Error Code Tabelle: .............................................................................................. 57
Before starting each adjustment procedure, set the oscilloscope to the following basic
settings:
X-Section:
TIME/DIV. (TB-A)
TIME VAR. (TB-A)
NORM (trigger)
TRIG. (coupling)
TRIG. LEVEL
TRIG. (SLOPE)
HOLD OFF
XY
X-POS.
X-MAG. x10
ALT/B Timebase
Y-Section:
CH I
CH II
INV CH I & II
Y-POS I & II
EXTern (trigger)
CAL.-Section
CALIBRATOR
If different settings are required, they are mentioned particularly for each subject.
Subject to change without notice
100ns (readout)
calibrated detent (A: 100ns)
off (NM LED dark)
AC (readout TR:...)
electrical center position (triggerpoint symbol in trace position)
rising slope symbol (readout TR:...)
minimum (HO LED dark)
off (XY not displayed in the readout)
electrical center position
off (X-MAG. x10 LED dark)
off (B time coefficient not displayed in the readout)
on, 5mV/div, calibrated, DC input coupling (readout CH1:5mV=)
off (deflection coefficient and input coupling not displayed in the readout)
off (both INV LEDs dark)
electrical center position
off (TR: EXT... not displayed in the readout)
1 kHz
Table of Contents
43