Pwc22/52 Connectors And Jumper Settings - Vaisala PWD22/52 User Manual

Vaisala present weather detector
Table of Contents

Advertisement

Appendix B ____________________________________ PWC22/52 Connectors and Jumper Settings
APPENDIX B
PWC22/52 CONNECTORS AND
JUMPER SETTINGS
VAISALA ______________________________________________________________________ 107
X1-1
Chassis (GND)
X1-2
RS-485 (B) (WHT)
X1-3
RS-485 (A) (BRN)
X1-4
DC power for measurement electronics (+, RED)
1)
X1-5
DC power for measurement electronics (-, BLK)
1)
X2-1
RS-232 (GND, GRY)
X2-2
RS-232 (TxD, GRN)
X2-3
RS-232 (RxD, YEL)
X2-4
Module 5
X2-5
Module 4
X2-6
Module 3
X2-7
Module 2
X2-8
Module 1
X3-1
Background Luminance Sensor PWL111 (Range, YEL)
X3-2
Background Luminance Sensor PWL111 (Level, GRN)
X3-3
Background Luminance Sensor PWL111 (+5 VA, RED)
X3-4
Background Luminance Sensor PWL111 (AGND, BLK)
X3-5
Separate heating power input for PWH111hood heaters
1)
(+, BRN/GRN and WHT/GRN)
X3-6
Separate heating power input for PWH111hood heaters
1)
(-, WHT/YEL and YEL/BRN)
X3-7
PWH111hood heater foil (+)
1)
X3-8
PWH111hood heater foil (-)
1)
X3-9
Ext Voltage +12 V (analog output current source (PNK)
X3-10
Ext (modem) control 1
X3-11
Ext (modem) control 2
X3-12
Analog output current sink (range is chosen by jumper X13
located under the PWC15PB), (BLU)
X4-1
Temperature sensor PT100 (+, BLU)
X4-2
Temperature sensor PT100 (+, YEL)
X4-3
Temperature sensor PT100 (-, RED)
X4-4
Temperature sensor PT100 (-, GRN)
X4-5
Ext relay control 3 (default) or Ext voltage +12 V (chosen by
jumper X11), (VIO)
X4-6
Ext relay control 1 (GRY/PNK)
X4-7
Ext relay control 2 (RED/BLU)
X4-8
GND
X5 and X8
Not used

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pwd22Pwd52

Table of Contents