5.4.2 DEF Tank Mounting and Installation

The DEF tank should be located to avoid heat sources or stagnant hot air build up which
will lead to overheating of the DEF.
Proper distance and elevation from DEF injector –ref 5.4
Ease of tank drain
Ease of filling with care taken regarding spillage
Tank fill vent away from HVAC air intake (unpleasant odor in cab may result)
Out of direct sunlight preferred
The tank must be +/-5° from horizontal when filling with DEF
An anti-friction mat is recommended under the tank base.
Table 5.5 below details the weight of the Standard DEF tank options when filled with DEF
to 100% full.
Volume
Configuration
19L
Landscape
19L
Portrait
38L
Landscape

5.4.3 DEF Tank Straps

The Perkins supplied DEF tanks feature grooves to help locate the tank straps. The groove
tolerances are shown in table 5.6 below. The Mandatory requirements are detailed in section
2 and must be adhered to.
The strap design must consider both the static assembled conditions plus the loads from
machine operation that are typically used as design points for a given machine. It is
recommended that FEA is conducted on the tank and mounting design.
A&I manual Publication TPD 1832 – Production issue 3.
Table 5.4 - DEF tank Volumes
Dimensions L, W, H (mm)
457.2 x 203.2 x 304.8
304.8 x 203.2 x 457.2
571.5 x 203.2 x 457.2
Table 5.5 – DEF Tank Mounting Details
Table 5.6 – DEF Tank Groove Tolerances.
1204F - DEF System Supplement
Weight (g) – 100%
DEF fill level
26270
26513
49444
Page 35 of 41