2. Locate the NCG valve on top of the large refrigerant tank.
3. Pull the ring for approximately 10 s.
4. Mount the front cover again.
5. Put the device back into operation.
6. Repeat the procedure the next day if necessary.
10

Cleaning and maintenance

 Clean the exterior of the device with a damp cloth as required. If
necessary, use a small amount of dishwashing detergent. Do not use
solvents or scouring agents.
 Check the service hoses (10) and (11) and the service couplings (12)
and (13) for damage regularly. Do not start up the
AirCon Service Center if it is damaged.