Download Print this page
IDEC HS1L Series Instruction Sheet

IDEC HS1L Series Instruction Sheet

Solenoid type safety switch, inside connector type

Advertisement

Quick Links

INSTRUCTION SHEET - HS1L Series
INSTRUCTION SHEET
Original Instructions
Solenoid Type Safety Switch
HS1L Series
Inside Connector type
Thank you for purchasing this IDEC product. Confirm that the delivered product is
what you have ordered. Read this instruction sheet to make sure of correct operation.
S A F E T Y P R E C A U T I O N S
In this operation instruction sheet, safety precautions are categorized in order of
importance to Warning and Caution :
WARNING
Warning notices are used to emphasize that improper operation may cause severe
personal injury or death.
CAUTION
Caution notices are used where inattention might cause personal injury or damage to
equipment.
1
Type
Circuit Code
Main
Door monitor
Lock monitor
circuit
circuit
DQ : 1NC + 1NC
1NO
1NC + 1NC
DT : 1NC + 1NC
1NC
1NC + 1NC
Solenoid voltage / Lock Mechanism
4 : 24V DC / Spring Lock
7Y : 24V DC / Solenoid Lock
Indicator voltage
4 : 24V DC
[0] : Without Indicator
Manual unlock key
[blank] : Without Manual Unlock Key
K : With Manual Unlock Key
Type Nos. in [ ] are not supplied as standard. Contact IDEC if required.
CAUTION
Solenoid lock type
• This safety switch is designed to lock the actuator while the solenoid is energized
and to release it when deenergized.
• When the power to the solenoid is interrupted by accident, such as disconnection,
the lock is released before a machine stops ompletely. Then, the worker may be
exposed to hazards.
• This safety switch can be used only for limited applications which do not
especially need to be locked for safety.
2
Specifications and Ratings
Applicable Standards
EN ISO / ISO14119, GB14048.5
IEC60947-5-1, EN60947-5-1
GS-ET-19, UL508, CSA C22.2 No.14
GB14048.5
Standards for Use
IEC60204-1/EN60204-1
Interlocking device Type
Type 2 Interlocking device
/ the level of coded
/ low level coded actuator (EN ISO / ISO14119)
Applicable Directives
Machinery Directive, Low Voltage Direc ive
Operating Temperature
Operating
Operating Humidity
Condition
Storage Temperature
Pollution Degree
Altitude
Impulse withstand voltage ‹Uimp›
2 5kV 
Rated insulation voltage ‹Ui›
250V
Thermal Current ‹Ith›
2.5A
Contact Ratings
( Reference Values )
‹Ue, Ie›
Class of Protection
Class II (IEC61140) *1
HS1L-DQ44KMSRPC-G
Indicator Color
G : Green
circuit
R : Red
1NO
1NC
-20 to +55°C (no freezing)
45 to 85%RH (no condensation)
-40 to +80°C (no freezing)
3
2,000m maximum
(Between ground and LED, solenoid circuit : 1.5kV)
(Between ground and LED, solenoid circuit : 30V)
30V 125V 250V
Resistive load (AC-12)
2.5A 2.5A 2.5A
AC
Inductive load (AC-15)
2.5A 2.5A 2.5A
2.5A 2.2A 1.1A
Resistive load (DC-12)
DC
Inductive load (DC-13)
2.5A 1.1A 0.6A
Solenoid Type Safety Switch, Inside Connector type
Operating Frequency
Operating Speed
B10d
Mechanical Durability
Electrical Durability
Shock Resistance
Vibration Resistance
Actuator Tensile Strength
when Locked
Direct Opening Travel
Direct Opening Force
Contact Resistance
Degree of Protection
Conditional short circuit current
Short-circuit protective device
Rated Operating Voltage
Rated Current
Turn ON Voltage
Turn OFF Voltage
Rated Power Consumption
Rated Operating Voltage
Rated Current
Light Source
Lens Color
Weight
Ratings approved by safety agencies
(1) TÜV rating
AC-15 250V, 2.5A
DC-13 30V, 2.5A
*1 Basic insulation of 2.5kV impulse withstand voltage is ensured between different
contact circuits and between contact circuits and LED or solenoid in the enclosure.
When both SELV (safety extra low voltage) or PELV (protective extra low voltage)
circuits and other circuits (such as 230V AC circuits) are used for the solenoid
power and contact circuits at the same time, the SELV or PELV requirements are
not met any more.
*2 See item 8 Dimensions.
*3 The actuator locking strength is rated at 3,000N of sta ic load. Do not apply a load
higher than the rated value. When a higher load is expected to work on the
actuator, provide an additional system consisting of another safety switch without
lock (such as the HS5D safety switch) or a sensor to detect door opening and stop
the machine.
*4 F1max. is maximum force. The actuator's guard-locking force Fzh is calculated in
accodance with GS-ET-19:
*5 When applicable connector and 1m cable (0.3mm
*6 Make sure that a fast acting fuse for short-circuit protection trips before overheating
of the wires.
Ind c v loa (
900 operations/hour
0.05 to 1.0 m/s
2,000,000 (EN ISO 13849-1 Annex C Table C.1)
1,000,000 operations min. (GS-ET-19)
100,000 operations min.
(900 operations / hour, Rated Load)
1,000,000 operations min.
(900 operations / hour, 24V AC/DC 0.1A Resistive Load)
Damage Limits
1,000m/s
2
Operating Extremes 10 to 55 Hz, half amplitude 0 35 mm
Damage Limits
30 Hz, half amplitude 1.5 mm
Fzh=3,000N minimum
F1max.=3,900N minimum (GS-ET-19) *2, *3, *4
11mm min.
50N min.
300mΩmax. (Initial value) *5
IP67 (IEC60529)
100A (250V)
250V, 10A fast acting type fuse *6
24VDC 100%ED
200mA (Initial value)
Rated Voltage × 85% max. (at 20° C)
Rated Voltage × 10% min. (at 20° C)
Approx. 5W
24VDC
10mA
LED
R(Red), G(Green) (Φ12 Lens)
Approx. 450g
(2) UL , c-UL rating
(3) CCC rating
2.5A, 250V ac, General Use
2.5A, 250V ac, Resistive
2.5A, 30V dc
maximum force (F1max )
=
Fzh
Safety coefficient (=1.3)
AWG22) are connected.
2
2016.08
B-1908-1(0)
1 1A 0 6A
AC-15 2.5A, 250V ac
DC-13 2.5A, 30V dc
( 1 / 6 )

Advertisement

loading

Summary of Contents for IDEC HS1L Series

  • Page 1 30 Hz, half amplitude 1.5 mm Actuator Tensile Strength Fzh=3,000N minimum Thank you for purchasing this IDEC product. Confirm that the delivered product is when Locked F1max.=3,900N minimum (GS-ET-19) *2, *3, *4 what you have ordered. Read this instruction sheet to make sure of correct operation.
  • Page 2: Mounting Examples

    INSTRUCTION SHEET - HS1L Series 2016.08 Solenoid Type Safety Switch, Inside Connector type B-1908-1(0) Actuator Mounting Reference Position Mounting Examples • As shown below, the mounting reference position of the actuator inserted into the safety switch is the actuator cover or stop film touches the safety switch lightly. (After •...
  • Page 3: Precautions For Operation

    • Use wires of a proper size to meet voltage and current requirements. CAUTION • HS1L Series Safety Switches are Type 2 low-level coded interlocking devices (EN ISO / ISO14119). The following system installation & mounting instructions are EN ISO / ISO14119 requirements to prevent function failure from the interlock switch.
  • Page 4: Contact Operation

    INSTRUCTION SHEET - HS1L Series 2016.08 Solenoid Type Safety Switch, Inside Connector type B-1908-1(0) Conduit hole Contact Operation Safety Switch connector Contact Configuration and Operating Characteristic Terminal Number Identification Type Contact Configuration *10 Operating Characteristic (reference) When wiring, the terminal number on each contact is...
  • Page 5 INSTRUCTION SHEET - HS1L Series 2016.08 Solenoid Type Safety Switch, Inside Connector type B-1908-1(0) Example of wiring Diagram realizing Safety Category Example of a circuit diagram for Safety Category 3 Example of a circuit diagram for Safety Category 4 (attainable PL = d)
  • Page 6: Dimensions (Mm)

    2-6-64 Nishimiyahara Yodogawa-ku, Osaka 532-0004, Japan EU Authorized Representative:IDEC Elektrotechnik GmbH Heselstuecken 8, D-22453 Hamburg, Germany DECLARATION OF CONFORMITY We, IDEC CORPORATION 2-6-64, Nishimiyahara Yodogawa-ku,Osaka 532-0004, Japan declare under our sole responsibility that the product: Description: Safety Switch Model No: HS1L-C to which this declaration relates is in conformity with the EC Directive on the following standard(s) or other normative document(s).

This manual is also suitable for:

Hs1l-dq44kmsrpc-gHs1l-dt44kmsr-rHs1l-dt44kmsrp-rHs1l-dq44kmsr-gHs1l-dq7y4kmsrp-rHs1l-dq44kmsr-r ... Show all