Product Description And Electrical Requirements - Scotsman C0522R Installation Manual

Hide thumbs Also See for C0522R:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
C0522 through C1030
Remote Condenser Models - Installation Manual

Product Description and Electrical Requirements

Dimensions (cm)
w x d x h
57.7*** x 61 x 58.5
same
78*** x 61 x 58.5
same
same
78*** x 61 x 74
same
** ERC211 has two circuits, when two C0522s or
C0530s are connected to it, fan motor relay kit
KCMR-230 must be used to control the fan motor.
*** Maximum width at top panel.
Ratings include the remote condenser motor, as it
is designed to be powered by the ice machine. If
connecting remote condenser independently of the
ice machine, use the information on the
condenser's dataplate for fuse and wire sizes.
Table notes: Medium cube models have the same
electrical characteristics as Small. Series revision
code omitted. All the listed condensers include a
headmaster valve.
Model
Electrical
C0522MR-6
230/50/1
same
same
C0530MR-6
same
same
same
C0630MR-6
same
C0830MR-6
same
C1030MR-6
same
June 2007
Use condenser
ERC111-6
ERC211-6**
ERC111-6
ERC211-6**
ERC311-6
ERC311-6
ERC311-6
Precharged tubing kits:
The ice making head's and the remote condenser's
refrigeration circuits must be connected. They are
designed to be connected using precharged
refrigerant tubing, supplied in kits of liquid and
discharge tubes. Several lengths are available,
order the one that just exceeds the length needed
for the site.
3 meters
6 meters
RTE10
RTE20
No additional refrigerant is required.
Note: Refrigerant charge is supplied with the ice
machine.
Page 6
Maximum
Fuse Size
15
15
15
15
20
30
20
12 meters
22 meters
RTE40
RTE75

Advertisement

Table of Contents
loading

Table of Contents