MC1448, MC1848, MC2148
Remote Cooled User Manual

Product Description and Electrical Requirements

Dimensions
Model
w" x d" x h"
MC1448SR-32
MC1448SR-3
MC1448MR-32 208-230/60/1
MC1848SR-32
48 x 24 x 29
MC1848MR-32 208-230/60/1
MC1848SR-3
MC2148SR-3
MC2148MR-3
*Or HACR circuit breakers.
Table notes: Series revision code omitted. All the
listed condensers include a headmaster valve.
Ratings include the remote condenser motor, as it
is designed to be powered by the ice machine. If
connecting remote condenser independently of the
ice machine, use the information on the condenser's
dataplate for fuse and wire sizes.
Central Condenser (Rack) Coils
The ice machine may be connected to a central
condenser coil. The requirements are:
• Coil – not previously used with mineral oil system.
Virgin coil preferred.
• Correct size (internal volume) and capacity (BTUH).
• Includes a headmaster valve for discharge pressure
control. Headmaster kit available for certain MAC
condensers, kit number is RCKCME6GX.
Note: Do not use MC1848R or MC2148R with MAC
• Fan motor on all the time or controlled to be on
whenever the ice machine is operating.
• U.L. listed for the ice machine
• Non-Scotsman condensers must have prior
Scotsman Engineering approval for warranty
coverage to be in effect.
Electrical
Use
condenser
208-230/60/1
ERC311-32
208-230/60/3
ERC311-32
ERC311-32
208-230/60/1
ERC611-32
ERC611-32
208-230/60/3
ERC611-32
208-230/60/3
ERC611-32
208-230/60/3
ERC611-32
Refrigerant tubing kits:
The ice making head's and the remote condenser's
refrigeration circuits must be connected. They are
designed to be connected Scotsman refrigerant
tubing, supplied in kits of liquid and discharge tubes.
Several lengths are available, order the one that just
exceeds the length needed for the site.
MC1448,
MC1848,
MC2148
No additional refrigerant is required.
June 2022
Page 4
Minimum
Maximum
Circuit
Fuse* Size
Ampacity
17.0
30
12.9
30
17.0
30
17.8
20
17.8
20
13.4
20
21.5
30
21.5
30
10'
25'
40'
BRTE10 BRTE25 BRTE40 BRTE75
Suggested
Fuse* Size
20
15
20
20
20
20
30
30
75'

Advertisement