Download Print this page

Riello PRESS 140 T/N Installation, Use And Maintenance Instructions page 10

Heavy oil burners

Advertisement

The adjustment of the air shutters shall be set each time, with reference to the nozzles deliveries and the combustion
chamber pressurization.
Fig. 2
Fig. 2 shows the positioning of the air shutters.
Fig. 3 shows the positioning of the cams of the motor.
Air shutters adjustments
st
stage: manual regulation carried out by acting on the sector A (fig. 2).
1
nd
rd
2
-3
stage: carried out by acting on the coloured lever of the motor (fig. 3).
Blue lever: adjustment not necessary.
Positioned by the factory on the vertical of the motor axis. It maintains the shutters of 2
closed during the 1st stage operation and in the stop periods.
Do not turn clockwise (-) the lever to avoid crawlings of the air shutters, turning the lever anticlockwise
(+) the motor will be in different position during the passage from 2nd to 1st stage or during the stop.
nd
Orange lever: for 2
rd
Red lever: for 3
stage air shutters adjustment, it is adjustable both in opening and closing position.
Black lever: it controls the opening of the 2
The control of the 3
5831
AIR SHUTTERS ADJUSTMENTS
stage air shutters adjustment, it is adjustable both in opening and in closing position.
nd
stage oil valve. It has always to anticipate the orange lever.
rd
stage valve is automatic through one of the cam next to the red lever.
Fig. 3
9
nd
rd
- and 3
stage