Alcatel ADP One Series User Manual page 46

Table of Contents

Advertisement

Control (Inputs)
Monitoring system M3
2/3
Remote control plug connection
(M3 monitoring)
1
18
19
34
Wiring customer
supplied
S1
NOTE : The contact is considered to be closed if the DC voltage
between 5 and 30 V is applied.
These contacts can be supplied by terminals 47 (OV) and
49 (+12V).
S1 : OPEN Remote control valid / Keyboard locked
S1 : CLOSE Keyboard valid / Remote control locked
S2 : On / ADP switching off
S3 : On / ROOTS switching off if the selection "Roots control"
has been validated
S4 : Purge Switching on / off if the selection "Purge control"
has been validated in the help menu with keyboard.
Monitoring system before V2.02 version
Note: If the remote control receives an order from the RS232,
keyboard and remote control are locked. Only LOC order
transmitted by the RS232 allows to enable keyboard or
remote control. (Contact Alcatel)
Alcatel - High Vacuum Technology - User's Manual ADP/ADS
0V
21
22
23
20
24
25
41
44
Emergency stop
Arrêt d'urgence
S2
S3
B 140
17
33
47
50
S4
+12V