Remote control
elements
(11)
(3a)
(10)
(9)
(8)
(1)
Numerical display, 4 digits (metric / imperial)
Displays welding parameters and error codes.
(2)
Limit switch function, change direction / stop
Depending on the switch position, the welding carriage changes direction or
stops as soon as the limit switch is activated.
(3a) White symbol: Oscillation dwell time, left
Regulates the oscillation dwell time on the left.
Yellow symbol: Return travel path
Return time at the end of the welding path in seconds [s].
(3b) White symbol: Oscillation dwell time, middle
Regulates the oscillation dwell time in the middle of the weaving motion.
Yellow symbol: Segment path with welding
Sets the length of the individual welding segments in [cm].
(3c) White symbol: Oscillation dwell time, right
Regulates the oscillation dwell time on the right.
Yellow symbol: Segment path without welding
Sets the distances between the individual segments in [cm].
(4)
Oscillation speed
Regulates the oscillation speed.
(5)
Offset
Regulates the offset during weaving.