6.3.3. Service mode

This function can be used to perform a review of the permeation rate at the membrane dryer during preventive service
without the need to dismount the device. This check can be used to determine whether it may have to be exchanged.
The control unit must already be in setup mode to be able to use the service mode (see 6.3). When activating the service
mode, the solenoid valve will be permanently engaged, which means that only the measuring gas flows through the control 
unit.
This function can be deactivated manually, otherwise the control unit resets this function automatically after 30 minutes.
...
Power
20
35
55
Test
50
40
32
°F
P
ressure
D
ew
P
oint
...
65 80 100
Value
23
5 -15
°F
...
Power
20
35
55
Test
50
40
32
°F
P
ressure
D
ew
P
oint
...
65 80 100
Value
23
5 -15
°F

7. Maintenance and servicing

7.1. Maintenance schedule

Maintenance

Function testing and visual inspection

Visual inspection
Changing filter element
Change filter element
7.1.1. Function testing and visual inspection
To ensure that the unit is in proper working order, the unit operator must perform regular function tests and visual
inspections:
Perform function tests and check purge air outlet, housing (for damage), system (for leakage), electrical connection (for
damage)
Check whether there are any errors or faults
→ For detailed instructions, see "9. Troubleshooting and repair" on page 32
Inspect the unit for dirt and contamination and clean it, if necessary
→ For detailed instructions, see "Cleaning" on page 31
BEKOMAT
®
check function
→ Press the test button
Check float drain function
→ Turn up the knurled screw (left-hand thread) and turn it down completely
DRYPOINT
M intelligence
®
Activation Press and hold the >>Test<< button for 10 seconds.
Activation is displayed (all green LEDs are flashing)
Releasing the >>Test<< button: Valves engages, only the measuring gas flows
All green LEDs flash in a 2 second cycle during service mode.
Deactivation Press and hold the >>Test<< button for 10 seconds.
Activation is displayed (all green LEDs are flashing)
Releasing the button: The device returns to the setup mode, changes of the settings can 
now be performed.
If no buttons will be actuated during 10 seconds, then the device will change to normal
mode.
Installation and operation instructions
regularly
annually
Interval