7.1.5. Permeation rate measurement

NOTICE
The device is subjected to operating pressure and electrical voltage
While performing maintenance works, the device is subjected to operating pressure and electrical 
voltage
The following preconditions must be established before the measurement for measurement of the permeation rate – as the
condition assessment of the membranes themselves.
  A cquisition of a suitable volume flow meter with a range of 0.4 – 4 cfm (atmospheric) with hose connection (approx. 40 
inch)/plug connection with connection thread G1/4 (BSPP - British Standard Pipe Parallel)
Setting of the DRYPOINT
be made available inside of the device)
Measurement sequence
Unscrew the blind plug at the head of the membrane dryer
The exiting purge area is depressurized
  S crew in connection G1/4 (BSPP - British Standard Pipe Parallel) of the hose connection volume flow meter into the 
thread G1/4 (BSPP - British Standard Pipe Parallel) in the head
  M anually closing/pasting the purge air outlet
Read the measuring result
After the measurement, the connection in the head of the membrane and dryer must be closed again by using the blind
plug, the purge air output at the sieve must be cleared. The device must be returned to normal mode "6.3.3. Service mode"
on page 27.
Recommended limit values in l/min: app. 25% of the maximum purge air volume DRYPOINT
(measuring gas flow share). 
30
Only for the tasks described in the following
M intelligence to operating mode "Service Mode", see 6.3.3 (only the measuring gas flow will 
®
M intelligence plus 0.2 cfm
®
DRYPOINT
M intelligence
®
US-EN