3.2. Installation

When installing the DRYPOINT
flows from left → right, the purge air outlet (2) faces forward.
For maintenance and servicing, we recommend installing a bypass line (1). Take into account that there should be around
30 cm space for the operation of the control unit.
Install the supplied long nipples and the check valve in the outlet assembly of the membrane dryer (mount in flow 
direction, see arrow on check valve).
The purge air must flow freely from the section covered by the screen (2).
The room in which the unit and the accessory equipment are installed must not house units that might release chemical
substances.
The unit must be installed in a room that is protected against frost. The ambient temperature as well as the compressed
air temperature must be between +35 and +122 °F.
Before installing the unit, thoroughly clean the existing pipelines and devices. (e.g. by blowing out).
Seal all threads with Teflon tape → do not use liquid sealants.
Install the unit so that the filter can be changed easily without causing damage to the drying system.
DRYPOINT
M intelligence
®
 M intelligence, observe the direction of flow of the compressed air. If the compressed air 
®
1
Installation and operation instructions
30 cm / 12`