Note – Status=1 is returned if valid data and no further records in the status buffer
Status=2 is returned if valid data and there are still records in status buffer
Status=3 is returned if valid data but the buffer is full (eg may have lost data)
Status=6 is returned if there are no new records
This buffer is updated when screens are moved. It is also updated automatically every 60 seconds.
It needs to be polled regularly to clear the stored data otherwise it will get full and records will be
lost. Even though screens may not be moving the data is being updated even though the status is the
same
Response Type No
Connect IP Module
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Example of string from module
192.168.0.32 3001
Up
192.168.0.32 3001
Up Receive 130, 1, 1
192.168.0.32 3001
Status Change Receive 9999
192.168.0.32 3001
Get Module Status
192.168.0.32 3001
Get Module Status Receive 167, 0, 255, 255, 255, 255, 255, 255, 255, 255
192.168.0.32 3001
Status Change Receive 9999
192.168.0.32 3001
Get Module Status
192.168.0.32 3001
Get Module Status Receive 167, 6, 255, 255, 255,
Moving top
Moving bot
Moving PP1
Moving PP2
Moving PPT
Moving PPB
At TOP
At BOTTOM
At PP1
At PP2
Stopped manual
Error
Spare
Fail-timeout
Fail – current
Rattle
At PPT
At PPB
Send
30 1
Send 67 3781
Send 67 3781
255, 255, 255, 255, 255