15. CONTROL COMMANDS
a. These commands are used to control the operation of screens.
b. The Switch groups and IR groups must be programmed according to section 5
c. Unified address is MAF address plus 16 e.g. Module 1 is Unified address 17
Operate Module Direct
COMMAND
Value
30
31
32
33
36
d. Command followed by value 0 operates all modules connected via Connect Network
including the Connect IP module
(e.g.: 30 0 will operate all devices connected via the Connect network)
e. Example of direct command
Connected to 192.168.0.32:3001 – command 30 1 using module ID would see the screen
move to up position
IR Group Commands
f.
IR group control can be used to control screens directly if connected via Connect Network
including the Connect IP module
g. Each module will require programming via register 75, as per point 11 in document
h. Example of direct command
Connected to 192.168.0.32:3001 – command 20 1 ,would see all screens programmed to
operate on IR group 1 move to up position
i.
Command followed by value 0 operates all modules connected via Connect Network
including the Connect IP module
Description
Module ID
Operate Module UP
Module ID
Operate Module PARTIAL 1
Module ID
Operate Module PARTIAL 2
Module ID
Operate Module DOWN
Module ID
Operate Module STOP

Advertisement