2.5 ATEX / IECEx certification
The D2xB1XH1 and D2xB1XH2 xenon beacons comply with
the following standards:
EN60079-0:2012+A11:2013 / IEC60079-0: ed. 6.0 (2011-06)
EN60079-15:2010 / IEC60079-15: ed. 4.0 (2010-01)
EN60079-31:2014 / IEC60079-31:2013 ed. 2.0 (2013-11)
Certificate No.
DEMKO 14 ATEX 4786493904X
IECEx ULD 14.0004X
The D2xB1XH1 Xenon Beacon is rated as follows:
II 3G Ex nA IIC T2 Gc Ta -40°C to +50°C
II 3D Ex tc IIIC 80°C Dc Ta -40°C to +50°C
The D2xB1XH2 Xenon Beacon is rated as follows:
II 3G Ex nA IIC T1 Gc Ta -40°C to +50°C
II 3D Ex tc IIIC 105°C Dc Ta -40°C to +50°C
CE Marking
2813
Zones, Gas / Dust Groups and Temperature
Classification
When connected to an approved system the D2xB1XH1 and
D2xB1XH2 xenon beacons may be installed in:
Zone 2 explosive gas air mixture not likely to occur
in normal operation, and if it does, it will only exist
for a short time.
Zone 22 explosive dust air mixture not likely to occur
in normal operation, and if it does, it will only exist
for a short time.
May be used with gases in groups:
Group IIA
propane
Group IIB
ethylene
Group IIC
hydrogen / acetylene
Having a temperature classification
(for Gas applications) of:
T1
450ºC
T2
300ºC
T3
200ºC (D2xB1XH1 only)
May be used with Dust types:
Group IIIA
combustible flyings
Group IIIB
non-conductive dust
Group IIIC
conductive dust
Maximum Surface Temperature for Dust Applications:
XH1 80°C & XH2 105°C
Installation must be carried out in compliance with the latest
issue of the following standards:
EN60079-14 / IEC60079-14: Explosive atmospheres -
Electrical installations design, selection and erection
EN60079-10-1 / IEC60079-10-1: Explosive atmospheres -
Classification of areas. Explosive gas atmospheres
EN60079-10-2 / IEC60079-10-2: Explosive atmospheres –
Classification of areas. Explosive dust atmospheres
_______________________________________________________________________________________________________________________________
European Safety Systems Ltd. Impress House, Mansell Road, Acton, London W3 7QH
Document No. D211-00-251-IS-SC
Issue F
02-03-2020
2.6 Ingress Protection Ratings
The product is rated for ingress Protection as follows:
IP rating:
Type rating per UL50E / NEMA250: 4 / 4X / 3R / 13
To maintain the ingress protection rating, the two off cable
entries must be fitted with suitably rated, certified cable entry
and/or blanking devices during installation.
2.7 Electrical Ratings
Model No.
Voltage Range
D2xB1XH1
20-28Vdc
D2xB1XH2
20-28Vdc
Table 1: Electrical Ratings
It is important that a suitable power supply is used to run the
equipment. The power supply selected must have the
necessary capacity to provide the input current to all the
units.
The input current will vary according to the voltage input
level.
For detailed max and surge current ratings of the device
please see Section 13.

3) Special Conditions of Use

Special Condition for safe Use as stated on the Type
Examination Certificate DEMKO 14 ATEX 4786493904X /
CoC IECEx ULD 14.0004X:
When used for a Group III application, the surface of the
enclosure may store electrostatic charge and become a
source of ignition in applications with a low relative humidity
<~30% relative humidity where the surface is relatively free of
surface contamination such as dirt, dust, or oil.
Guidance on protection against the risk of ignition due to
electrostatic discharge can be found in EN TR50404 and IEC
TR60079-32.
End user shall adhere to the manufacturer's installation and
instruction when performing housekeeping to avoid the
potential for hazardous electrostatic charges during cleaning,
by using a damp cloth.
To maintain the ingress protection rating and mode of
protection, the cable entries must be fitted with suitably rated,
certified
cable
entry
and/or
installation. If conduit is used for installation, seal conduit
within 18 inches from the enclosure.
sales@e2s.com
www.e2s.com
Sheet 2 of 9
IP66
blanking
devices
during
Tel: +44 (0)208 743 8880
Fax: +44 (0)208 740 4200

Advertisement