4. ADJUSTMENTS
TO ADJUST WATER LEVEL
Make sure the refill tube is inserted into the overflow tube.
Check that the water level is at the water line inside the
toilet tank. If the level is off, hold the middle of the float rod,
and carefully bend the rod up or down as needed.
TO ADJUST REFILL TIME
To adjust the refill time, first loosen the locknut. Turn the
timing screw clockwise to increase the refill time; counter-
clockwise to decrease the time. After adjustment, tighten
the locknut.
Kohler Co., Kohler, WI
Refill Tube
Float Rod
Fig. #10
Refill Tube
Float Rod
Fig. #11
5
Overflow
Tube
Water
Level
Overflow
Tube
Water
Level
AA
110282-2-
(9515)