CFM
0.00
0.10
Rpm
Bhp
Rpm
Bhp Rpm
3500
450
0.30
495
0.46
3700
476
0.35
519
0.53
3900
502
0.41
543
0.60
4100
527
0.48
566
0.68
4300
553
0.55
591
0.77
4500
579
0.63
615
0.87
4700
604
0.72
639
0.97
4900
630
0.81
664
1.08
5100
656
0.92
688
1.20
5300
682
1.03
713
1.33
5500
707
1.15
738
1.47
5700
733
1.28
763
1.61
5900
759
1.42
787
1.77
6100
784
1.57
812
1.93
CFM
1.00
1.10
Rpm Bhp
Rpm Bhp
3500
925
1.78
962
1.97
3700
933
1.88
971
2.07
3900
940
1.97
979
2.17
4100
946
2.05
986
2.27
4300
951
2.15
992
2.37
4500
957
2.24
998
2.47
4700
963
2.35
1003
2.58
4900
970
2.48
1009
2.70
5100
978
2.62
1016
2.83
5300
988
2.78
1024
2.98
5500
999
2.95
1033
3.15
5700 1012
3.15
1044
3.34
5900 1025
3.36
1056
3.55
6100 1040
3.60
1069
3.78
LEGEND
Bhp — Brake Horsepower
ESP — External Static Pressure
Table 13 — Evaporator Fan Performance — 50XCA14 Units
0.20
0.30
Bhp Rpm Bhp
Rpm Bhp
537
0.56
583
0.65
633
558
0.64
600
0.73
646
580
0.72
619
0.83
661
602
0.82
639
0.93
678
625
0.92
659
1.04
696
648
1.03
681
1.15
715
671
1.14
702
1.28
734
694
1.27
724
1.41
755
718
1.40
746
1.56
776
741
1.54
769
1.71
797
765
1.69
792
1.88
819
789
1.85
815
2.05
841
813
2.02
838
2.23
863
838
2.20
862
2.42
886
1.20
1.30
Rpm Bhp
Rpm Bhp
Rpm
997
2.15
1030
2.32
1061
1007
2.27
1041
2.46
1072
1016
2.38
1051
2.59
1083
1024
2.49
1059
2.71
1093
1030
2.60
1067
2.83
1101
1036
2.71
1073
2.94
1108
1042
2.81
1079
3.06
1115
1047
2.93
1085
3.18
1121
1053
3.06
1090
3.31
1126
1060
3.20
1096
3.44
1132
1068
3.37
1103
3.60
1137
1077
3.55
1110
3.77
1144
1087
3.75
1119
3.97
1152
1099
3.97
1129
4.18
1160
ESP (in. wg)
0.40
0.50
0.60
Rpm
Bhp Rpm
0.76
687
0.89
742
0.84
696
0.96
748
0.93
707
1.05
756
1.03
720
1.15
765
1.15
735
1.26
776
1.27
751
1.39
789
1.40
768
1.52
804
1.55
786
1.67
820
1.70
806
1.83
837
1.86
826
2.00
855
2.03
846
2.18
874
2.22
867
2.37
894
2.41
888
2.57
914
2.62
910
2.79
934
ESP (in. wg)
1.40
1.50
1.60
Bhp
Rpm
Bhp
Rpm
2.50
1090
2.67
1119
2.65
1103
2.83
1131
2.79
1114
2.99
1143
2.93
1124
3.14
1154
3.06
1133
3.29
1164
3.18
1141
3.43
1173
3.31
1149
3.56
1181
3.43
1155
3.69
1188
3.56
1161
3.83
1194
3.70
1166
3.97
1200
3.85
1172
4.11
1205
4.02
1178
4.28
1211
4.20
1184
4.45
1217
4.41
1192
4.65
1223
NOTES:
1. Units are available with several motor hp options. Refer to Table 1.
2. Static pressure losses for any options or accessories must be
applied to external static pressure before entering the fan perfor-
mance table.
3. Interpolation is permitted; extrapolation is not.
4. Fan performance is based on 1 in. standard throw-away filter, unit
casing, and wet DX (direct expansion) coil losses at sea level.
30
0.70
0.80
Bhp Rpm Bhp
Rpm Bhp
1.05
793
1.23
841
1.41
1.12
799
1.29
847
1.48
1.19
805
1.37
852
1.56
1.29
811
1.45
858
1.64
1.40
820
1.55
865
1.73
1.52
830
1.67
872
1.84
1.65
842
1.80
882
1.96
1.80
855
1.94
892
2.10
1.96
870
2.10
905
2.26
2.14
886
2.28
919
2.43
2.32
903
2.46
934
2.62
2.52
921
2.67
950
2.82
2.73
940
2.88
968
3.03
2.95
960
3.11
986
3.27
1.70
1.80
Bhp
Rpm
Bhp
Rpm
Bhp
2.83
1146
3.00
1172
3.16
3.01
1159
3.19
1186
3.37
3.19
1172
3.38
1199
3.57
3.35
1183
3.56
1211
3.77
3.51
1194
3.73
1222
3.95
3.66
1203
3.90
1232
4.14
3.81
1212
4.06
1241
4.31
3.95
1219
4.22
1249
4.48
4.10
1226
4.37
1257
4.64
4.24
1232
4.52
1263
4.80
4.39
1238
4.67
1269
4.96
4.55
1243
4.83
4.72
4.91
0.90
Rpm
Bhp
885
1.60
892
1.68
898
1.76
903
1.84
909
1.93
915
2.03
922
2.15
931
2.28
941
2.43
953
2.59
966
2.78
980
2.98
996
3.19
1013
3.43
1.90
Rpm
Bhp
1198
3.32
1211
3.54
1225
3.76
1237
3.97
1249
4.17
1260
4.37
1269
4.56
1278
4.74
1286
4.91

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omnizone 50xca08Omnizone 50xca12Omnizone 50xca14Omnizone 50xca16Omnizone 50xca24Omnizone 50xca06-24 ... Show all