CFM
0.00
Rpm
Bhp
Rpm
6000
496
1.03
533
6250
517
1.17
552
6500
537
1.31
571
6750
558
1.47
590
7000
579
1.64
610
7250
599
1.82
629
7500
620
2.02
649
7750
641
2.23
669
8000
661
2.45
688
8250
682
2.69
708
8500
703
2.94
8750
9000
9250
9500
CFM
0.80
Rpm
Bhp
Rpm
6000
789
2.81
6250
800
3.00
6500
6750
7000
7250
7500
7750
8000
8250
8500
8750
9000
9250
9500
LEGEND
Bhp — Brake Horsepower
ESP — External Static Pressure
Table 7 — Condenser Fan Performance — 50XCA14 Units
0.10
0.20
Bhp
Rpm
Bhp
1.17
570
1.36
1.31
588
1.50
1.46
605
1.65
1.62
623
1.81
1.79
642
1.99
1.98
660
2.18
2.18
679
2.38
2.39
697
2.59
2.61
716
2.82
2.85
ESP (in. wg)
0.90
1.00
Bhp
Rpm
Bhp
Rpm
ESP (in. wg)
0.30
0.40
Rpm
Bhp
Rpm
Bhp
608
1.58
646
1.82
624
1.72
660
1.97
640
1.88
675
2.13
657
2.05
691
2.30
674
2.23
707
2.49
691
2.42
723
2.68
709
2.62
739
2.89
726
2.84
1.10
1.20
Bhp
Rpm
Bhp
NOTES:
1. Units are available with several motor hp options. Refer to Table 1.
2. Static pressure losses for any options or accessories must be
applied to external static pressure before entering the fan perfor-
mance table.
3. Interpolation is permitted; extrapolation is not.
4. Fan performance is based on unit casing, and wet DX (direct
expansion) coil losses at sea level.
24
0.50
0.60
Rpm
Bhp
Rpm
Bhp
683
2.06
719
2.31
696
2.22
732
2.48
710
2.39
744
2.66
724
2.57
757
2.85
739
2.76
754
2.96
0.70
Rpm
Bhp
755
2.56
766
2.74
778
2.93

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Omnizone 50xca08Omnizone 50xca12Omnizone 50xca14Omnizone 50xca16Omnizone 50xca24Omnizone 50xca06-24 ... Show all

Table of Contents