GE IC3645SR3R404P2 Installation And Operation Manual page 31

Separately excited (sx) transistorized dual motor controllers
Table of Contents

Advertisement

DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
The first byte of data sent to the
-35
"master" control has timed out.
MEMORY RECALL
NO
SYMPTOM
Control does not operate.
Circuits valid
POSSIBLE CAUSE
for
Loss of the RS232 connection between the
Traction
master and slave controls.
•=
Controller
•=
•=
•=
P21 in the slave control is not at battery volts
when the key switch is turned on.
•=
Controller unit is defective.
Replace control.
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
The function setting did not transfer
-36
from the master control to the slave
control.
MEMORY RECALL
NO
SYMPTOM
Control does not operate.
Circuits valid
POSSIBLE CAUSE
for
Defective controller unit.
Traction
•=
Controller
CORRECTIVE ACTIONS
PY11 in the slave control is not connected.
PY12 in the master control is not
connected.
PY12 in the slave control is not connected.
PY11 in the master control is not
connected.
Verify the connection between P21 and the
key switch.
CORRECTIVE ACTIONS
Replace control.
CAUSE OF STATUS INDICATION
This status code will be displayed when the master
control does not receive the first byte of data when
expected.
TROUBLE-SHOOTING DIAGRAM
KEY SWITCH
P1
PY11
PY12
MASTER
CONTROL
CAUSE OF STATUS INDICATION
This status code will be displayed when the function
settings of the master control do not transfer to the
slave control.
TROUBLE-SHOOTING DIAGRAM
NO GRAPHIC FOR THIS
STATUS CODE
Page 31
P1
P21
PY12
PY11
SLAVE
CONTROL
July 1999

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic3645sr3r404p3

Table of Contents