GE IC3645SR3R404P2 Installation And Operation Manual page 19

Separately excited (sx) transistorized dual motor controllers
Table of Contents

Advertisement

DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Brake pedal depressed while motoring
-04
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
POSSIBLE CAUSE
for
Defective brake potentiometer.
Traction
Controller
Brake pedal depressed while trying to motor.
TRACTION
DESCRIPTION OF STATUS
STATUS CODE
Start switch fails to close.
-05
MEMORY RECALL
NO
SYMPTOM
Control will not operate.
Circuits valid
for
POSSIBLE CAUSE
Defective start switch circuit.
Traction
•= Check start switch to insure closure when
Controller
accelerator is depressed.
•= Check for open circuit or loose connections in
wiring from brake switch to start switch and
from P3 to start switch.
Defective accelerator switch.
•= Check accelerator switch potentiometer for
proper operation and ohmic value.
CORRECTIVE ACTIONS
CORRECTIVE ACTIONS
CAUSE OF STATUS INDICATION
This status code will be displayed when P13 is .25
volts greater than the low learn point and 5 seconds
have timed out in motoring.
TROUBLE-SHOOTING DIAGRAM
KEY
SWITCH
P2
P1
P9
P13
P8
BRAKE POT
CAUSE OF STATUS INDICATION
This status code will be displayed when the
accelerator (P7) is calling for greater than 40% on-
time, while the start switch (P3) is less than 60% of
battery volts.
TROUBLE-SHOOTING DIAGRAM
KEY SWITCH
L
P1
P17
P2
P6
Page 19
P3
P4
P5
P7
P8
P9
ACCPOT