Service scans
Service level summary
Function
Entry
Relay test
Press the 9 and OK buttons simultaneously for
approximately 2 seconds
Temperatures and
Press the 9 and r buttons simultaneously for
quick scan
approximately 2 seconds
Operating
Press
conditions
Press the r and OK buttons simultaneously for
Fault history
approximately 2 seconds
Press the # and r buttons simultaneously for
Resetting Codings
approximately 2 seconds; press the D button;
to the factory
confirm with OK
default
Coding 1
Press the 9 and # buttons simultaneously for
approximately 2 seconds
Coding 2
Press the # and r buttons simultaneously for
approximately 2 seconds; confirm with OK
24
Exit
Press the OK button