Circuit Board Coil Driver Modules; Truck Management Module (Tmm); Hydraulic Pump Control - GE IC3645SR4R404U2 Installation And Operation Manual

Separately excited (sx) transistorized dual motor traction controllers and series pump control
Table of Contents

Advertisement

BASIC OPERATION AND FEATURES
SX TRANSISTOR CONTROL
112). This feature allows the operator to select the best
vehicle performance for changing factory (task) conditions.
Section 2.3.7 Circuit Board Coil Driver Modules
Coil drivers are internal to the control card, and are the
power devices that operate the Line, 1A and SP contactor
coils. On command from the control card, these drivers
initiate opening and closing the contactor coils. All driver
modules are equipped with reverse battery protection, such
that, if the battery is connected incorrectly, the contactors
can not be closed electrically.
Section 2.3.8 Truck Management Module (TMM)
The Truck Management Module is a multifunction
accessory card (IC3645TMM7A), or an integral function of
the GE Pump controls when used with the SX Traction
control. The Module provides the OEM the ability to initiate
status codes or operator warning codes to be displayed on
the Dash Display, whenever a normally open switch or
sensor wire provides a signal to the Module.
The TMM Module can be used to display a separate status
code indicating over-temperature of traction motors,
hydraulic motors, or any other device or system that can
activate a switch that closes.
The TMM Module can also be used as a Brush Wear
Indicator (BWI). The Brush Wear Indicator is designed to
detect a "worn out brush" and display a fault code on the
Dash Display to warn maintenance personnel that the
motor brushes need to be replaced before they wear to the
point of causing destructive damage to the motor
commutator surface.
Section 2.4 Hydraulic Pump Control
This hydraulic motor controller consists of the following
features:
•=
Four speeds, adjustable from O to 100% motor volts.
Fixed speeds actuated by switch closure to negative.
•=
P1A bypass contactor (if required)
•=
Variable resistor input (5K-O ohms). Control starts
when input is reduced to below 3.5 volts.
•=
PMT functions available when a pump contactor is
used.
•=
Current limit and controlled acceleration adjustable.
•=
Battery Discharge Indicator interrupt compatible.
Operation of voltage regulator card: This card provides the
basic functions required for controlling the pump control,
optional contactors, and PMT functions. Battery positive is
applied through a main control fuse to the key switch,
energizing the control card power supply input to P1.
When a pump contactor is used, PMT operation is the
same as outlined for the traction controllers.
The four speed (motor volts) reference points P12, P19, P20
AND P21 are selected by connecting these points
independently to battery negative.
The first speed is obtained by closing Speed Limit I (P12) to
control negative. SLl is adjustable by Function 11 using the
Handset to adjust motor voltage from O to 100%. The
specified motor volts will be regulated, however, the
magnitude of motor current will vary depending on the
loading of the vehicle.
The second speed is obtained by closing SL2 (P19) to
control negative. SL2 is adjusted using the Handset and
Function 12 similar to SL1.
The third speed is obtained by closing SL3 (P20) to control
negative. SL3 is adjusted using the Handset and Function
13 similar to SL1.
The fourth speed is obtained by closing SL 4 (P21) to
control negative. SL4 is adjusted using the Handset and
Function 14 similar to SL1. PIA will close 0.2 seconds after
controlled acceleration stops. Speed Limit 4 (Function 14)
must be activated and set to >250 to enable the optional P 1
A contactor.
If more than one Speed Limit is activated, the selected
speed with the highest motor volts will override the low
motor volt speed. The current limit circuit is adjustable and
operates the same as the traction current limit.
The controlled acceleration circuit is adjustable and
operates the same as the traction circuit. Adjustment range
is from 0.1 to 5.5 seconds.
The variable resistor input will override the fixed motor volt
limits set by the four (4) adjustable Speed Limits. It will vary
motor volts above the set limits up to full motor volts, and
closes P1A as resistance is decreased to less than 200
ohms.
The Battery Discharge Indicator (BDI) interrupt will disable
the hydraulic controller if the connection at P10 loses the
12 volt signal from the traction control. BDI interrupt can be
disabled by Function 17 using the Handset. Select card type
with or without BDI function.
Page 10
October 1998

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ic3645sp4r400u2

Table of Contents