ADJUSTABLE FEATURES
SX TRANSISTOR CONTROLS
FUNCTION 51
MODE 1 RATIO
(Push CONT 4)
This function sets the ratio between armature and field
current when transitioning from minimum field to maximum
field current. The setting represents the quantity of field
current changed for each 1 amp of armature current
changed.
Max
Max
Fld Ref
Change
Set
20
.24
0 to 10
30
.24
0 to 10
40
.27
0 to 10
50
.48
0 to 10
60
.48
0 to 10
This RATIO takes effect when the Mode 1 settings are
called for by the Interactive Dash Display.
FUNCTION 52
MODE 2 ARMATURE CONTROLLED
ACCELERATION AND 1A TIME
(Push CONT 5)
Same as Function 48.
This C/A AND 1A TIME takes effect when the Mode 2
settings are called for by the Interactive Dash Display.
FUNCTION 53
MODE 2 FIELD WEAKENING START
(Push CONT 6)
Same as Function 49.
This FIELD WEAKENING START takes effect when the
Mode 2 settings are called for by the Interactive Dash
Display.
FUNCTION 54
MODE 2 MINIMUM FIELD CURRENT
(Push CONT 7)
Same as Function 50.
This MINIMUM FIELD CURRENT takes effect when the
Mode 2 settings are called for by the Interactive Dash
Display.
FUNCTION 55
MODE 2 RATIO
(Push CONT 8)
Same as Function 51.
This RATIO takes effect when the Mode 2 settings are
called for by the Interactive Dash Display.
Resolution
Example
Per Unit Value
If Set at 5
0.024
0.12 amps
0.024
0.12 amps
0.027
0.135 amps
0.048
0.24 amps
0.048
0.24 amps
FUNCTION 56
MODE 3 ARMATURE CONTROLLED
ACCELERATION AND 1A TIME
(Push CONT 9)
Same as Function 48.
This C/A AND 1A TIME takes effect when the Mode 3
settings are called for by the Interactive Dash Display.
FUNCTION 57
MODE 3 FIELD WEAKENING START
(Push CONT 10)
Same as Function 49.
This FIELD WEAKENING START takes effect when the
Mode 3 settings are called for by the Interactive Dash
Display.
FUNCTION 58
MODE 3 MINIMUM FIELD CURRENT
(Push CONT 11)
Same as Function 50.
This MINIMUM FIELD CURRENT takes effect when the
Mode 3 settings are called for by the Interactive Dash
Display.
FUNCTION 59
MODE 3 RATIO
(Push CONT 12)
Same as Function 51.
This RATIO takes effect when the Mode 3 settings are
called for by the Interactive Dash Display.
FUNCTION 60
MODE 4 ARMATURE CONTROLLED
ACCELERATION AND 1A TIME
(Push CONT 13)
Same as Function 48.
This C/A AND 1A TIME takes effect when the Mode 4
settings are called for by the Interactive Dash Display.
FUNCTION 61
MODE 4 FIELD WEAKENING START
(Push CONT 14)
Same as Function 49.
This FIELD WEAKENING START takes effect when the
Mode 4 settings are called for by the Interactive Dash
Display.
FUNCTION 62
MODE 4 MINIMUM FIELD CURRENT
(Push CONT 15)
Same as Function 50.