Changing the Oras Electra 6575
circuit card
Removing the damaged circuit card
– Switch off the electricity to the urinal flusher.
– Close the water inlet to the urinal flusher.
– Remove the control box cover.
– Remove the mains connector (11) e.g. by prying off
with a small screwdriver.
– Detach the wires (31) from the solenoid valve con
nectors (32).
– Detach the photocell sensor cable (5) (coming from
the IR sensor) from its connector.
– Undo the protection plate screw (41).
– Remove the protection plate (40).
– Undo the circuit card screws (42).
– Remove the damaged circuit card (43) from the
control box.
Installing a new circuit card
– Introduce the new circuit card (43) into the control
box and tighten the screws (42) as shown.
– Fasten the protection plate (40) back in place with
the screw (41) as shown.
– Attach the wires (31) to the solenoid valve
connectors (32).
– Attach the sensor cable (5) to its connector.
– Press the mains connector (11) back in place.
– Open the water inlet to the urinal flusher.
– Switch on the electricity.
– Adjust the recognition range and afterflow.
– Fasten the control box cover.
3
1
8
4
3
2
3
ORAS LTD
Isometsäntie 2
P.O. Box 40
FI-26101 Rauma
Finland
Tel. +358 (0)2 83 161
Fax +358 (0)2 831 6300
Info.Finland@oras.com
www.oras.com
6
Oras Data Terminal
5
7
32
31
11
40
41
43
42

Advertisement

loading

Summary of Contents for Oras Electra 6575

  • Page 1 Changing the Oras Electra 6575 circuit card Removing the damaged circuit card – Switch off the electricity to the urinal flusher. – Close the water inlet to the urinal flusher. – Remove the control box cover. – Remove the mains connector (11) e.g. by prying off with a small screwdriver.
  • Page 2 – Työnnä IR-tunnistimen anturikaapeli (5) paikalleen. – Sätt på spänningen till armaturen. – Työnnä liitin (11) paikalleen. – Sätt på locket på el-boxen. – Avaa vedentulo huuhtelulaitteelle . – Kytke virta huuhtelulaitteelle. – Suorita tunnistusetäisyyden ja jälki-virtaama-ajan säätö. – Asenna ohjauslaatikon kansi. Oras Data Terminal...

This manual is also suitable for:

19858964141500397136414150039751