EMERGENCY RELEASE

Carry out only after power supply to the motor has been interrupted!
In the event of a power supply failure, release the gearmotor, so that you can move the
boom by hand.
To do so, use the RIB key supplied and turn it in the clockwise sense, until the stop is
reached (Pic. 12).
By doing so, the barrier boom works independent from the gearmotor and it can be moved
by hand.
When power is supplied again, turn the key counterclockwise strongly until you block it.

MAINTENANCE

To be undertaken only by specialized staff after disconnecting power supply.
After every 100.000 cycles check:
- boom balance (see the paragraph "ADJUSTING THE BALANCING SPRINGS");
- the tightness of the release knob (see the paragraph "EMERGENCY RELEASE");
- the tightness of the boom holding attachment and the implantation of the boom (see the
paragraph "ASSEMBLING THE BOOM");
- the wear on the mechanical stops and the limiti switch setting (see the paragraph "LIMIT

ELECTRIC CONNECTIONS

POINT A - CONTROL PANEL FEATURES
J4
J1
S3
TR2
J9
J5
J2
J3
J1
L-N
J2
COM
LSC
LSO
LSSC
LSSO
TLC
PHOT. NC
EDGE NC
COM
D+ TEST
D+
J8
D-
J3
OPEN 2
SIGNAL
AERIAL
J4
U - MOTOR
V-W - MOTOR
J5
OK CLOSE
OPEN 1
J7
CLOSE
STOP
J6
K BUTT.
COM
J6
PROBE
J7
RADIO
J8
AUX. ATT.
J10
J9
SW PARK
J10
SW RADIO
S3
PROG.
TR2
TRIMMER LOW SPEED
SWITCH SETTING").
- Grease the bearings of the boom carrier shaft and the threaded spring guide bar.
The described maintenance is vital for the corrected operation of the product in
the time.
PARK CRX
Main power supply 230Vac 50/60Hz upon request)
Common contact
Closing limit switch contact (NC)
Opening limit switch contact (NC)
Closing slowing down limit switch contact (NO)
Opening slowing down limit switch contact (NO)
Vehicle presence signal (NO) (only when switched to PARK mode)
Photocells contact (NC)
Safety strip contact (NC)
Common contact
Safety strip self-test power supply +12Vdc 500mA max
Accessories power supply +12Vdc 500mA max
Accessories power supply -12Vdc 500mA max
Barrier opening button 2 contact (NO) (only when switched to PARK mode)
Barrier open signal 12Vdc
Buzzer - Acoustic signal connection (12Vdc max 200 mA)
Radio antenna
Blinker (max 40W)
Motor common connection
Motor inverters and condenser connection
Immediate closure command contact (only when switched to PARK mode)
Open1 button contact (NO)
Close button contact (NO)
Stop button contact (NC)
Single pulse button (NO)
Common contact (common line for all the commands and safety inputs)
Heating probe connection terminal block (code ACG4666 optional)
Built in radio module
Card 1 relay connector (code ACQ9080) for management of courtesy light or
boom arm locking magnet
Card 3 relay connector (code ACQ9081) for management of courtesy light or
boom arm locking magnet and traffic lights.
DO NOT TOUCH THE JUMPER!
IF REMOVED THE OPERATOR DOES NOT FUNCTION!
DO NOT TOUCH THE JUMPER!
IF REMOVED THE RADIO SYSTEM DOES NOT FUNCTION!
Programming button
Slow closure speed electronic regulator
G
B
12
code AC07063

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rapid s metalAa50070fAa50079f

Table of Contents