Page 1
K500 With functioning in hold-to-run man mode when the safety devices are failing. Operator Power Supply Max gate weight Max Thrust Max torque Code K500 230V 50/60Hz 500 kg / 1103 lbs 400 N 9,5 Nm AA33694...
(for example by installing inside a locked board). 2° - For the section and the type of the cables RIB advices to use a cable of H05RN-F type with 1,5 sqmm minimum section and, however, to keep to the IEC 364 and installation standards in force in your country.
Page 4
INSTALLATION K500 CHECKING BEFORE THE INSTALLATION !! THE GATE SHALL MOVE FRICTIONLESS !! N.B.: Gate features must be uniformed with the standards and laws in force. The door/ gate can be automated only if it is in a good condition and its conditions comply with the EN 12604 norm.
MOTOR AND RACK FITTING The rack shall be fitted over the motor support, at a certain distance from it. Its height can be adjusted thanks to the holes In the rack. The height is adjusted to prevent the gate from resting on the driving gear of the K as it moves (Fig.
Page 7
Vite Autom. TC CR 5x10 TRIL UNI8112 CAL1155 Corona elicoidale CPL1203 Flangia finecorsa DAE55x16 Vite aut. TE 5.5x16 P.Tronca Z CAL1166 Carcassina + campana motore K500 CPL1206 Boccola DDD6MA Dado autob. 6MA ALTO CCA1179 Perno cerniera scatola QE CPL1236 Scatola QE...
Page 8
Declaration of incorporation for partly completed machinery - Machinery Directive 2006/42/EC, Annex II., B R.I.B. S.r.l. - Via Matteotti, 162 - 25014 Castenedolo - Brescia - Italy Tel. ++39.030.2135811 - www.ribind.it - ribind@ribind.it K500 Apparatus model : Object of the declaration : The following essential requirements of the Machinery Directive (2006/42/EC) are abided by and applied: ·...