ETC ColorSource ThruPower User Manual page 19

Table of Contents

Advertisement

100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
Mod-Square: The mod-square curve provides a
non-linear relationship between control level and
voltage. For most tungsten lamps, this provides
the best relationship between brightness and
level, and is the default.
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
Fluorescent: The fluorescent curve provides a
linear curve which steps to 46% level when the
level is raised above zero – this is helpful with
dimmable fluorescents and other non-tungsten
loads. This initial voltage is 47% of the
incoming voltage.
Menu structure
100%
Control Input
100%
Control Input
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
Control Input
Linear: The linear curve provides a
linear relationship between input
control level and output voltage.
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
Control Input
Preheat: The preheat curve provides a
fixed preheat at 5% of the incoming
voltage (12V assuming a 230V input).
Preheat is used to extend lamp life when
lamps are being turned on rapidly from
cold.
100%
100%