14. TECHNICAL DATA

Controlled device
Supply voltage
Maximum inlet and outlet load
Maximum power consumption
Temperature measurement range
Temperature adjustment range
Temperature adjustment precision
Hysteresis range
Visual signalling
Operation temperature
Storage temperature
Protection level
Colour
Assembly method
Controller weight with cables
Cable length
Norms, approvals, certificates
Warranty period
Size (width/height/depth) mm
15. COMPOSITION OF THE SET
a) sensor with 2 temperature sensors
b) sensor bands
c) rawbolts
d) instructions
e) fixing scheme
16. INFORMATION ON ELECTRONIC WASTE MANAGEMENT
We did our best to make our controller work as long as possible. The device is
subject to natural wear and tear. If it does not meet your requirements any
longer, please bring it to electronic waste collection point. Local electronic
equipment distributors offer free waste collection services.
Incorrect management of electronic waste result in environmental pollution.
Cardboard packages should be collected as scrap paper.
central heating pump and hot water pump
230 V 50 Hz
3 A 230 V 50 Hz
1.6 W
from -5ºC to +120ºC
from +20ºC to +80ºC in central heating mode
from +20ºC to +70ºC in hot water tank mode
1ºC
2ºC - 10ºC
backlit LCD screen
from -5ºC to +40ºC
from 0ºC to +65ºC
IP40
black
wall, rawbolts
0.72 kg
controller feeder cable: 1.5 m
central heating pump feeder cable: 1.5 m
hot water pump feeder cable: 1.5 m
tank temperature sensor: 5 m
boiler temperature sensor: 1.5 m
Conformity with EMC and LVD directives, RoHs
2 years
150/90/52
7