EUROSTER 11E - USER MANUAL
CENTRAL HEATING/UTILITY HOT WATER SYSTEM PUMP CONTROLLER
MANUFACTURER: P.H.P.U. AS, Polanka 8a/3, 61-131 Poznań, POLAND
1. INTRODUCTION
In order to guarantee correct operation of central heating or hot usable water controller and
installations one should familiarize oneself with the present user manual.
2. FIELD OF APPLICATION
EUROSTER 11E is a modern controller that controls central heating circulating pump or hot
water tank loading pump.
3. CONTROLLER FUNCTION
prevents boiler sweat (CH system control mode)
keep constant temperature in the tank (UHW system control mode)
anti-stop function to protect pumps against stoppage
frost protection
pump operation test
temperature reading correction
The EUROSTER 11E controller features the Anty-Stop function that prevents idle pump rotors
against seizing. Once the heating season is over, every 14 days the function automatically
turns ON the pumps for 30 seconds. To that end the controller must be left powered up.
4. VISIBLE CONTROLLER ELEMENTS
EUROSTER 11E
1. 230 V 50 Hz mains input
2. 230 V 50 Hz power supply to pump
3. Input for temperature sensor cable
4. Mains switch
5. LCD display
6. Knob
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 11E and is the answer not in the manual?

Questions and answers

Summary of Contents for EUROSTER 11E

  • Page 1 In order to guarantee correct operation of central heating or hot usable water controller and installations one should familiarize oneself with the present user manual. 2. FIELD OF APPLICATION EUROSTER 11E is a modern controller that controls central heating circulating pump or hot water tank loading pump. 3. CONTROLLER FUNCTION prevents boiler sweat (CH system control mode) ●...
  • Page 2 EUROSTER 11E - USER MANUAL Screen backlight turns off by default after a minute of finishing controller operation. Controller makes it possible to set permanent backlight. (chapter 9). 5. INSTALLATION GENERAL SAFETY RULES It is necessary to read this user manual carefully prior to the ●...
  • Page 3: Controller Display

    EUROSTER 11E - USER MANUAL 6. CONTROLLER DISPLAY Elements of the controller display: 1. Name of the controlled parameter (displayed while set point values are browsed/set) 2. Heat source (boiler) temperature sensor icon (CH system control mode) 3. Manual operation mode (icon lit while the temperature is manually controlled) 4.
  • Page 4: Mode Of Operation

    EUROSTER 11E - USER MANUAL 8. MODE OF OPERATION The EUROSTER E11E controller may be operated in two modes: it may control CH system pump or UHW system pump. In the former mode the CH system pump is engaged if sensor temperature has exceeded the preset limit.
  • Page 5: Controller Operation

    EUROSTER 11E - USER MANUAL 4. Pump manual operation (test) Display current pump status commanded by the controller (0/1 = pump disengaged/engaged). Press the knob and modify the parameter value to manually control the pump. Press the knob once more or leave it inactive for 10 seconds to resume automatic mode of control.
  • Page 6: Specifications

    15. SIMPLIFIED DECLARATION OF EU CONFORMITY P.H.P.U. AS AGNIESZKA SZYMAŃSKA-KACZYŃSKA hereby declares that the type of EUROSTER 11E equipment conforms to the following directives: 2014/35/EU (LVD), 2014/30/EU (EMC), 2011/65/EU (RoHS). The complete text of the Declaration of EU conformity is available at the following Internet address: www.euroster.pl...
  • Page 7 EUROSTER 11E - USER MANUAL Central heating pump control mode EUROSTER 11E controller 2. CH boiler 3. Heat source temperature sensor 4. CH pump 5. Radiator (heat load) Utility hot water pump control mode 1. EUROSTER 11E controller 2. UHW tank temperature sensor 3.
  • Page 8: Electronic Waste Management Information

    EUROSTER 11E - USER MANUAL Utility hot water re-circulation pump control mode (the so called “third pipe”) 1. Controller EUROSTER 11E 2. Re-circulated water temperature sensor 3. Re-circulation pump 4. CH boiler with UHW tank 5. CH pump 6. Radiator (heat load)
  • Page 9 EUROSTER 11E - USER MANUAL GUARANTEE CERTIFICATE EUROSTER 11E Warranty terms: 1. Warranty is valid for 24 months from the controller sale date. 2. Claimed controller together with this warranty certificate must be supplied to the seller. 3. Warranty claims shall be processed within 14 business days from the date the manufacturer has received the claimed device.

Table of Contents