EUROSTER 11W – USER MANUAL
MANUFACTURER: P.H.P.U. AS, ul. Polanka 8a/3, 61-131 Poznań, Poland
1. INTRODUCTION
In order to ensure proper operation of the controller and of the CH system, please read this
manual carefully.
2. APPLICATION
EUROSTER
11W
interoperation with Central Heating (CH) coal- and pulverized coal-fired boilers in systems
equipped with furnace blowers.
The controller measures the temperature of water in the boiler and adjusts the air flow to the
furnace and controls the operation of the CH circulation pump.
EUROSTER 11W controller is equipped with an ANTI-STOP function that prevents
seizing of an idle pump rotor. It automatically turns the pump on for 30 seconds every
14 days
when
Keep the controller turned on to allow the function operation after the heating season.
3. CONTROLLER FUNCTIONS
ensure smooth adjustment of the blower rotational speed
⚫
ensure optimum operation of the boiler
⚫
prevent boiler condensation (sweating)
⚫
prevent boiler overheating – thermal protection
⚫
provide frost protection
⚫
provide the Anti-Stop function – protection of the blower and pump against seizure
⚫
ensure comfortable presetting with a knob
⚫
perform operation tests of the pump and of the blower
⚫
provide temperature readings correction
⚫
EUROSTER 11W
Installation and operation manual
Manual version: 11.05.2013.
is
a
state-of-the-art
the
microprocessor-based
heating
season
controller
designed
is
1
for
over.