EUROSTER 11K User Manual

EUROSTER 11K User Manual

Uni versal controller for water jacket fireplace central heating system

Advertisement

Quick Links

EUROSTER 11K CONTROLLER USER MANUAL
MANUFACTURER: P.H.P.U. AS, Polanka 8a/3, 61-131 Poznań, POLAND
1. FIELD OF APPLICATION
EUROSTER 11K universal controller for water jacket fireplace central heating systems is
equipped with switched 230 VAC outputs to connect the following system elements:
electrically controlled actuator of the fireplace combustion air throttle
plate heat exchanger water circulation pump
CH (central heating) system water circulation/buffer tank pump
DWH (domestic hot water) tank pump
and universal voltage-free contacts that may be used to turn on/off:
alternative heat source (e.g. a gas-fired boiler).
The controller may control systems built according to one of the three following layouts:
CH system with a plate heat exchanger
CH system with a heat buffer
CH system with a plate heat exchanger and a DWH tank.
In all layouts the controller adjusts the combustion processes by opening/closing the fireplace
throttle depending on the measured temperatures and information received from the
cooperating room thermostat. An alternative heat source (e.g. a gas-fired boiler) may also be
turned on depending on the temperatures and the information.
The EUROSTER 11K controller features the ANTY-STOP function that prevents idle pump
rotors and valves against seizing. Once the heating season is over, every 14 days the function
will automatically turn the pumps and the valves on for 30 seconds. To that end the controller
must be left powered up.
EUROSTER 11K
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 11K and is the answer not in the manual?

Questions and answers

Summary of Contents for EUROSTER 11K

  • Page 1 MANUFACTURER: P.H.P.U. AS, Polanka 8a/3, 61-131 Poznań, POLAND 1. FIELD OF APPLICATION EUROSTER 11K universal controller for water jacket fireplace central heating systems is equipped with switched 230 VAC outputs to connect the following system elements: electrically controlled actuator of the fireplace combustion air throttle ...
  • Page 2: Visible Controller Elements

    EUROSTER 11K CONTROLLER USER MANUAL 2. VISIBLE CONTROLLER ELEMENTS Lights Light ON means – ignition function ON – 1 sensor temperature reading displayed –alternative heat source ON – 1 pump ON – throttle open – room thermostat signal hooked up –...
  • Page 3 EUROSTER 11K CONTROLLER USER MANUAL Controller terminals: ATTENTION The controller must not be installed in a place where ambient temperature may exceed 40°C. ATTENTION The controller is equipped with an electronic power supply switch, which does guarantee safe isolation power circumstances.
  • Page 4: Operation

    EUROSTER 11K CONTROLLER USER MANUAL c) Connect additional heat source controller: unplug additional heat source controller from its power supply  link E11K controller box with alternative heat source controller box using at least 2 x  0.75 mm braided cord connect a cable to the AUX output COM and NC or NO terminals of the E11K controller ...
  • Page 5 EUROSTER 11K CONTROLLER USER MANUAL warning (critical) temperature. The controller also turns off automatically should the fireplace went out. It will happen after the time (in minutes) set as the value of the OF installer parameter. If the parameter is set to 0, automatic controller shut down is disabled.
  • Page 6 EUROSTER 11K CONTROLLER USER MANUAL controller/its sensor fails or in case of a power supply black out. f) Detection of sensor failures and other dangerous situations Following events are recognized by the controller: Event On screen Pumps AUX output Acoustic signal...
  • Page 7 EUROSTER 11K CONTROLLER USER MANUAL k) Relay activation delay To increase lifetime of the controller output relays, outputs are prevented against activating/ deactivating more frequently than once per second. However, lights signaling state of the relays go on/off without any delay.
  • Page 8 EUROSTER 11K CONTROLLER USER MANUAL Controller treats the fireplace as shut down and closes its throttle if the fireplace temperature has dropped down below tE. On the other hand the controller resumes normal operation after the ignition phase as soon as the temperature has risen above tE.
  • Page 9: System Layouts

    EUROSTER 11K CONTROLLER USER MANUAL If the modified setting depends on another more important (key) parameter, the  system will prevent any incorrect modification. For example, the throttle activation temperature may not be set higher than the alarm temperature. 6. SYSTEM LAYOUTS Use the SC service parameter to select the actual system layout.
  • Page 10: Specifications

     7. COMPATIBILITY WITH STANDARDS AND CERTIFICATES The E11K controller meets all requirements of the EMC and the LVD EU Directives. The CE Conformity Declaration is available on the http://www.euroster.com.pl Internet webpage. 8. SPECIFICATIONS a) Temperature range 0°C – 99°C...
  • Page 11 EUROSTER 11K CONTROLLER USER MANUAL GUARANTEE CERTIFICATE EUROSTER 11K Warranty terms: 1. Warranty is valid for 24 months from the controller sale date. 2. Claimed controller together with this warranty certificate must be supplied to the seller. 3. Warranty claims shall be processed within 14 business days from the date the manufacturer has received the claimed device.

Table of Contents