50 Mechanical installation

Placing the converter

The cabinet can be placed into its final position with an iron bar and a wooden piece at the
bottom edge of the cabinet. Place the wooden piece carefully to avoid damage to the cabinet
frame.
The cabinet has a back-to-back design, and thus you cannot install it with a longer side
against a wall.
The converter must be installed in an upright vertical position.
Notes:
• Leave a 400 mm (16 in) clearance above the converter cabinet.
• Leave space at the side for the coolant pipes.
• You can adjust the height, for example, if the floor is uneven by using metal shims between
the cabinet frame and floor.
> 600 mm (23.6 in)
> 400 mm (16 in)
> 600 mm (23.6 in)