Installing The System In The Rack - IBM N6000 Series Installation And Setup Instructions

Filer
Hide thumbs Also See for N6000 Series:
Table of Contents

Advertisement

FRONT
Left and Right
Rails
H1
H2
Chassis attach screw
H3
H4
H5
H6
H7
Chassis attach screw
H8
H9
Figure 3. N6000 rail mounting template
Note: When installed, each N6000 series filer enclosure will occupy a 6U space.
Using two silver pan head M5 screws, attach the rail to the front of the rack using holes H2 and H8.
Tighten these screws with a screwdriver.
3. At the rear of the rack, position the rail at the same EIA location used in step 2. Make sure that the
locating pins seat properly. Using two silver pan head M5 screws, attach the rail to the rack using
holes H2 and H8. Tighten these screws with a screwdriver.
4. Tighten the four rail adjustment screws on the installed rail.
5. Repeat steps 2 through 4 for the left-hand rail.

Installing the system in the rack

Use these instructions to install the N6000 series filer in the rack.
Section of rack EIA rail
Top rail screws
Locating pins
Locating pins
Bottom rail screws
REAR
Left and Right
Rails
H1
H2
1 EIA unit (1U)
H3
H4
H5
H6
H7
H8
H9
Installation and setup instructions
5