Setting storage expansion unit shelf IDs

Use these instructions to set the storage expansion unit shelf IDs.

Setting EXN4000 or EXN1000 storage expansion unit shelf IDs

A unique shelf ID (from 1 to 7) is required for each EXN4000 or EXN1000 in a loop.
Shelf ID 1 is used for the first unit in a new loop. Shelf IDs for additional units are incremented
sequentially from the number of the first unit.
To adjust the storage expansion unit shelf ID, press the - or + buttons.
Shelf ID - close-up view
Note: This illustration shows a detailed view of the EXN4000. The shelf ID buttons on the EXN1000 are
in the same relative position.

Setting SAS expansion unit shelf IDs

A unique shelf ID (from 00 to 98) is required for each SAS storage expansion unit in a SAS stack.
1
!
Figure 5. Shelf ID tab on the EXN3000
Mute button
Shelf ID
!
Gb switch
1Gb 2Gb
4Gb
(set to 2 Gb)
1Gb ELP
4Gb
2Gb
Installation and setup instructions
7