CHAPTER 5: INSTALL THE ACUSENSOR M
Shut OFF the installation site, branch Circuit Breaker. Failure to do so may result in serious
WARNING
personal or fatal injury. When uncertain whether power supply is disconnected, always verify
using a voltmeter.
All high voltage electrical connections must be made by licensed electricians according to
WARNING
National and Local electrical codes/regulations.
Permanent wiring shall be employed as required by local codes.
CAUTION
Keep all Incoming 120 VAC wiring separate from low voltage wiring within Header. 120 VAC
CAUTION
Power wires must be routed (separate from other wiring) located near the top of inside Header.
SECTION 5.1: Secure Sensor to Header
1. Turn OFF power.
2. Remove Cover from Sensor.
3. Remove (2) #10 x 1/2 inch Phillips Panhead screws from the cradles.
Sensor
DN 1574
4. Line up the predrilled screw holes located on the Mounting Plate with predrilled screw holes on the Header Cover.
5. Secure the Sensor to the Header Cover with (2) #10 x 1/2 inch Phillips Panhead screws.
Predrilled Screw Holes
DN 1575
SECTION 5.2: Install the Angled Spacer (Sold Separately)
Note:  The Angled Spacer is an option that is sold separately. To do so, please call Customer Service at 1-888-679-3319.
1. Turn OFF power.
2. Remove Cover from Sensor.
3. Seat the Sensor inside the Angled Spacer.
a. The flat side of Angled Spacer must butt up against the Header Cover.
4. Align the predrilled screw holes located on the Mounting Plate with the predrilled screw holes located on the Angled Spacer.
5. Secure the Sensor to the Header Cover with (2) #10 x 5/8 inch Phillips Panhead screws (supplied with the Angled Sensor Kit.
a. Do not use (2) #10 x 1/2" Phillips Panhead screws that were supplied with the Acusensor M kit.
8 of 28
Cover
www.NabcoEntrances.com
#10 x 1/2"
Phillips Head
Screw
Figure 1 XXXX
Predrilled
Screw Holes
Sensor
#10 x 1/2"
Panhead Screw
Figure 2 Recessed Track
Rev 8-25-17