Chapter 4: Presence Detection Area - Nabco Acusensor M Installation Manual

Table of Contents

Advertisement

www.NabcoEntrances.com
Rev 8-25-17
Specification
Mounting Height
Weight
Color
Full Color LED
Angled Spacer
Adjustable Detection Area
ECO Mode
Table 2 Electrical Wiring
Item
Input Voltage
Power Consumption
Output
Make sure total power consumption of all Sensors does not exceed the capability of the door control or power supply.
CHAPTER 4: PRESENCE DETECTION AREA
The Sensor is used to detect changes of multiple near-infrared rays that beam from the Sensor down to various points on the floor.
These various points reflect the near-infrared rays to form an grid in the shape of a square. To more acurately monitor a Presence
Detection Area, the grid is broken into invisible rows (Depth), and columns (Width).
Notice:  Width and depth of Presence Detection Area must comply with ANSI Standards.
Moun ng
Height
DN 1567
78 inches to 118 inches (2.0m to 3.0m)
Approximately 10 ounces (285g)
► Displays operating status
Black Cover or Silver Cover
The Angled Spacer is an option that is sold separately. To do so, please call Customer Service at
► For Slide doors only
1-888-679-3319.
► For increased depth range.
► Depth
► Width
Closes door earlier for a pedestrians moving away from door.
12-24 Volts AC or DC
3VA or less @ 24VAC
80mA or less @ 24VDC
► Non-polarized semi-conductor relay, N.O. or N.C.
150mA or less @ 12VDC
► Max. 100mA @ 30VAC/50VDC
Exceeding the rated output may result in malfunction or breakdown.
Row 1
Row 2
Row 3
Row 4
Row 5
Row 6
Description
Description
A B
AcusensorMInstallationManual
P/N C-00187
C
D
E
F
5 of 28

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents