CHAPTER 7: SWITCH SETTINGS 1-8
1. Turn OFF power.
2. Lift the resusable protection flap located on the Left hand side of Acusensor M.
a. Underneath the flap are three groups of Switches.
b. The backside of Flap shows a diagram for how to set switches 1 thru 8.
# Default Se ng
Opera on Mode
1
2
DN 1560
Opera on Mode
Output Logic
Input Logic
Width (L)
Width (R)
DN 1559
* Install Sensors on both sides of the Door
Output
Logic
3
# Normal
# N.O.
Doorway 2
* Doorway 1
First Row Off
Determines what part of the Presence Detec on Area (grid) is being monitored.
Normally Open/Normally Closed
Please refer to "Input Logic" Sec on
Adjusts width of Presence Detec on Area (grid) on the Le Side of Door independently
Adjusts width of Presence Detec on Area (grid) on Right Side of Door independently
Switches 17-20
Switches 9-16
Switches 1-8
Input
Logic
4
5
# High
N.C.
Low
Figure 5 Switch Setting Diagram located under Flap