Section 8.2: Learn Time (Switches 12 And 13) - Nabco Acusensor M Installation Manual

Table of Contents

Advertisement

www.NabcoEntrances.com
Rev 8-25-17
Table 11 Assigned LED Colors
Row
1
Red
No Light
2
Pale Blue
3
Yellow
4
Blue
5
Green
6
Purple
While in Area Check Mode, and every time the door opens, the Control will send a Test Command Input Signal to the Sensor. Before
the door starts to open, the Sensor LED will illuminate a blinking White light (4) times (10Hz), indicating communication between the
Control and Sensor is normal.
Table 12 LED Operating Status
While in Area Check Mode, the ECO Mode will become inactive, and Learn Time becomes 5 seconds.
Sensor Status
Recognized Test Command Input
Detected Depth Row 1 thru 6
Stand-by
 8.1.3 Depth Row Detection LED Lights
During normal operation, when a Depth Row is in Detection, the Sensor's LED will illuminate an assigned color.
If multiple Depth Rows are detected at the same time the Sensor's LED will illuminate the color assigned to the Depth Row closest to
Table 13 Assigned LED Colors
the face of Door.
Operation Mode
Depth Row 1
Normal
RED
Doorway I
Purple
Doorway II
Red
1st Row OFF
N/A
SECTION 8.2: Learn Time (Switches 12 and 13)
In the event a moving pedestrian decidedly stands still within the Presence Detection Area for
WARNING
a time longer than the "Learn Time", the door may close and cause
injury or entrapment.
After Power is turned ON, do not enter the Presence Detection Area for (1) minute.
WARNING
Notice:  Set Learn Time to 30 seconds or longer to comply with ANSI Standard.
Learn Time is when the Sensor learns that a stationary object is part of the area, and learns to ignore that object in order for the door
Table 14 Learn Time
to close. Learn Time differs due to the Switch Setting for Operation Mode and Switch Setting for Depth Row.
Operation Mode
Normal
Set: 15s, 30s, 60s, or 300s
Doorway 1
Set: 15s, 30s, 60s, or 300s
Doorway 2
Set: 15s, 30s, 60s, or 300s
1st Row OFF
Inactive
When Operation Mode is set to (Normal) or (Doorway 2)
When Operation Mode is set to (Doorway 1) or (1st Row)
White Light blinks (4) times
Assigned LED color
No Light
Depth Row 2
Red
Red
Row 1
Row 2
Set: 15s, 30s, 60s, or 300s
LED
LED
Depth Row 3
Depth Row 4
Orange
Orange
Orange
Row 3
Row 4
5 seconds (fixed)
5 seconds (fixed)
5 seconds (fixed)
AcusensorMInstallationManual
P/N C-00187
Sensor Operating Order
1
2
3
Depth Row 5
Depth Row 6
some
probability of severe
Row 5
Row 6
17 of 28