Through Roof Fan Cowls and Fan Kits
WIRING CONNECTIONS
For inline axial EC fan models (no capacitor):
FAN0531 / FAN0532 / FAN0533 / FAN0534
FAN0739 / FAN1009 / FAN1060 / DCT0189
Brown
P
Blue
N
Green/Yellow
E
For inline centrifugal fan models:
FAN0529 / FAN0530 / FAN0535 / FAN0740
P
N
E
TYPICAL INSTALLATION
Fasten tube to roof truss or rafter using clamp bracket supplied.
Tube/cowl must be mounted vertically to ensure weatherproofi ng
Flexible ducting connects directly to the
bottom of rigid duct. Cut any excess
length of ducting off before connecting.
Installation Instructions
enquiry@manrose.co.nz | www.manrose.co.nz
Motor
Red
Blue
Motor
Green/Yellow
White
2.0 F
CAP
Fix diffuser to ceiling and fasten ducting. If screw-fi xing diffuser is
supplied cut 153mm diameter hole. If diffuser is type with spring
loaded self-latching clip fasteners cut 205mm diameter hole.
Specifi cations are subject to change without notice
For inline centrifugal (3 speed) fan models:
FAN0967
White (3)
SP3/P
White (2)
SP2/P
White (1)
SP1/P
White (4)
N
Green/Yellow
E
2.0 F
CAP
Connect SP3/SP2/SP1 to single phase (P)
for High/ Medium/ Low speed control
For inline centrifugal (3 speed) fan models:
FAN1002
Black
SP3/P
Brown
SP2/P
White
SP1/P
Blue
N
Green/Yellow
E
2.0 F
CAP
Connect SP3/SP2/SP1 to single phase (P)
for High/ Medium/ Low speed control
Make electrical connections below roof
Motor
White (5)
White (6)
Motor
Violet
Grey
Page 3