2 Starting operation:

The flow-meter is delivered ready to use with following settings:
• Measuring volumes in litres, range 1 (standard mode).
• Presettable Batch Controller to 5 L (option).
• All ranges are calibrated to liquids similar to water.
Before installation remove protective caps and make sure that
• Liquid is compatible with the flow-meter material
• System pressure does not exceed the specified max. ratings

2.1 Mounting

The device must have the following run-in run out length.
R –In: minimum 75 cm with diameter ∅ = 1"
R –Out: minimum 75 cm with diameter ∅ = 1"
Flow- direction accordiung to arrow.
Installation position: upright, display up.
Never use mechanical tools to to screw down

3 Operating modes:

- Measuring of quantities in litres (standard mode)
- Measuring flow rate
- Presettable Batch Controller (option)
Changing between the modes is done with the key
After every press of
- Volume:
- Flow rate:
- Presetting:

3.1 Turn on

The device is turned on by pressing
when a minimum liquid flow is detected. In this case counting is started immediately.
Seite 3/8
the symbol of the chosen mode appears:
Vol
Flowrate
Preset
Operation manual DR15
or
. Furthermore the flow-meter starts operation
Rev 1.7e
16.10.06