4. Loosen the M5 hex locknuts on each retaining bracket and remove them. These are re-installed
later. Refer to
5. Lift the workstation off the frame and place it on a suitable work surface.
5.1.3

Remove the workstation from a Cabinet

If the workstation is mounted using the slide mount option, remove it from the furniture before servicing.
To remove the workstation from a Cabinet
1. Open the rear cabinet door.
2. Disconnect the cables that are connected to the back panel connectors of the workstation. Do not
disconnect the peripheral ends of the cables unless specifically instructed to do so. Tag the cables
so that they can be properly reconnected to the workstation.
3. Open the front cabinet door.
4. Remove the captivated panel fastener screws from the threaded inserts.
5. If the retaining brackets are attached, loosen the two captivated fasteners on each retaining bracket
and remove them. The following image illustrates the two captivated fasteners being removed.
6. If you are using a slide mount option, pull the slide try out and place the workstation on a suitable
work surface or you may service the workstation while still on the slide tray.
sectionInstalling workstation in Z and EZ
Console.