Download Print this page

Pump Discharge System Installation - Zoeller N153 Owner's Manual

Recirculating media filters
Hide thumbs Also See for N153:

Advertisement

The Zoeller Pump Company Recirculating Media Filter is designed as a secondary treatment device. It works in conjunction with the septic
tank (primary treatment) and the drain field (water disposal and final polishing) to provide excellent overall treatment of the onsite effluent.
Refer to the diagram below to see the overall flow of effluent through the system.
Figure 3: Pump Discharge Media Filter System Flow Schematic
SEPTIC TANK
General System Installation Outline
1. Install septic tank.
2. Install drain line as required to septic tank.
3. Install dosing tank.
4. Install piping between septic tank and dosing tank.
5. Install dosing tank pump.
6. Install wiring from dosing pump to control panel.
7. Install media filter (see detailed instructions below).
8. Install force main from dosing tank to media filter.
9. Install media filter pump.
10. Install wiring from media filter pump to control panel.
11. Install return line from media filter to 80/20 pressure flow splitter.
12. Install 80/20 pressure flow splitter at highest point.
13. Install return line from 80/20 pressure flow splitter to dose tank.
14. Install drain line from 80/20 pressure flow splitter to drain field.
Section 2: Pump Discharge System Installation
HOUSE
SEPTIC
SEWER
TANK
PRESSURE
SPLITTER
GRAVITY FLOW
TIMED DOSING
PANEL
20% TO DRAIN
FIELD SYSTEM
80% RECIRCULATION
© Copyright 2021. All rights reserved.
DOSE
TANK
80%
MEDIA
80/20
FILTER
FLOW
W/PUMP
20%
DISCHARGE
TO DISPOSAL FIELD
PRESSURIZED FLOW
80/20
PRESSURE
FLOW
SPLITTER
DOSE TANK
7
SK2097B
SK2229

Advertisement

loading