Download Print this page
Zoeller N153 Owner's Manual

Zoeller N153 Owner's Manual

Recirculating media filters
Hide thumbs Also See for N153:

Advertisement

Quick Links

Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.
Register your
Zoeller Pump Company Product
on our website:
http://reg.zoellerpumps.com/
Congratulations on the purchase of this Zoeller Pump Company
Recirculating Media Filter. This system will provide years of
trouble-free service when installed and serviced according to the
manufacturer's recommendations.
This manual incorporates the installation, operation, maintenance,
and service instructions into one document to aid in the ownership
of a Zoeller Pump Company Onsite Treatment System. Please

Table of Contents

Safety Instructions ........................................................................ 1
Limited Warranty ........................................................................... 2
Troubleshooting & Service Checklist........................................2
Preinstallation Checklist ............................................................. 3
Gravity Discharge System Installation .................................. 4-6
Pump Discharge System Installation .................................... 7-9
System Start-Up ........................................................................... 10
Operation & Maintenance .........................................................11
Owner's Information
Model Number: ________________________________________
Job Name: ____________________________________________
Distributor: ____________________________________________
Date of Purchase: ______________________________________
Contractor: ____________________________________________
Date of Installation: ____________________________________
System Readings During Operation: Voltage _____ Amps _____
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624
Recirculating Media Filters
OWNER'S MANUAL
© Copyright 2021. All rights reserved.
read and review this manual before installing the product. Follow
the steps and procedures listed within for a proper start-up.
Many items contained within, when followed correctly, will not
only ensure a long and problem-free life for the system, but
also save time and money during installation. Should further
assistance be necessary, please call Zoeller Pump Company at
1-800-928-7867.

Safety Instructions

TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR
PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY
INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION
AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH
THE PUMP.
This is a SAFETY ALERT SYMBOL.
When you see this symbol on the pump or in the
manual, look for one of the following signal words
and be alert to the potential for personal injury or
property damage.
Warns of hazards that WILL cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause serious personal
injury, death or major property damage.
Warns of hazards that CAN cause personal injury or
CAUTION
property damage.
INDICATES SPECIAL INSTRUCTIONS WHICH ARE
VERY IMPORTANT AND MUST BE FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS
PRIOR TO PERFORMING ANY WORK ON THIS PUMP.
MAINTAIN ALL SAFETY DECALS.
REFER TO WARRANTY ON PAGE 2.
SECTION: C3.20.140
CL0064
0321
Supersedes
0515
Visit our website:
zoellerpumps.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the N153 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Zoeller N153

  • Page 1: Table Of Contents

    Recirculating Media Filters http://reg.zoellerpumps.com/ OWNER'S MANUAL Congratulations on the purchase of this Zoeller Pump Company read and review this manual before installing the product. Follow Recirculating Media Filter. This system will provide years of the steps and procedures listed within for a proper start-up.
  • Page 2: Limited Warranty

    If the above chart does not uncover the problem, consult Zoeller Pump Company- Do not attempt to service or otherwise disassemble system or pump. © Copyright 2021. All rights reserved.
  • Page 3: Preinstallation Checklist

    General Preinstallation Checklist 1. Inspect your Recirculating Media Filter package. Occasionally 5. Most residential kits include a Zoeller model N153 pump. This products are damaged during shipment. If the unit is damaged, pump is 1/2 HP, 115V, single phase unit capable of delivering the contact your dealer before using.
  • Page 4: Gravity Discharge System Installation

    Section 1: Gravity Discharge System Installation The Zoeller Pump Company Recirculating Media Filter is designed as a secondary treatment device. It works in conjunction with the septic tank (primary treatment) and the drain field (water disposal and final polishing) to provide excellent overall treatment of sewage. Refer to the diagram below to see the overall flow of effluent through the system.
  • Page 5 Section 1: Zoeller Pump Company Recirculating Media Filter Gravity Discharge Figure 2: FRAME ALL STAINLESS PIPE CLAMP 14" 13" PIPE BOOT LINER 15" PIPE SEAL DETAIL 4" SLOTTED DRAIN PIPE 1-1/4" PVC PIPE FROM DOSE TANK 17" 4" DRAIN TO 80/20 TRU-FLOW SPLITTER...
  • Page 6 Section 1: Media Filter (Gravity) Installation Instructions 1. Excavate a hole for the media filter, large enough to build the liner 16. Place the hose clamp around the boot onto 1-1/4” penetration support walls. NOTE: Support walls should extend a minimum of pipe and tighten.
  • Page 7: Pump Discharge System Installation

    Section 2: Pump Discharge System Installation The Zoeller Pump Company Recirculating Media Filter is designed as a secondary treatment device. It works in conjunction with the septic tank (primary treatment) and the drain field (water disposal and final polishing) to provide excellent overall treatment of the onsite effluent.
  • Page 8 Section 2: Zoeller Pump Company Recirculating Media Filter Pump Discharge Figure 4: FRAME ALL STAINLESS PIPE CLAMP 13" 13" PIPE BOOT 6.5" LINER 15" PIPE SEAL DETAIL 1-1/4" PVC PIPE ZOELLER TO 80/20 PREWIRED CONDUIT PRESSURE FLOW SPLITTER FROM PUMP TANK 17"...
  • Page 9 Section 2: Media Filter (Pump Discharge) Installation Instructions Excavate a hole for the media filter, large enough to build the liner support Place the hose clamp around the boot onto 1-1/4” penetration pipe and walls. NOTE: Support walls should extend a minimum of 4” above the original tighten.
  • Page 10: System Start-Up

    7. Submersible Pump Installation Instructions (FM0447). 8. WW1 Filter owner's manual (CL0040). Record the float settings of the dose tank and recirculation basin on the drawings below. Typical Float Settings For Zoeller Model N153 Pumps MEDIA FILTER DOSE TANK 6" MIN.
  • Page 11: Operation & Maintenance

    (septic tank), secondary Any cleanout risers that have been damaged or buried need to be treatment device (Zoeller Pump Company RMF), and a soil distribution replaced or brought back to grade. component (gravity or pressurized leach lines or a drip field). Your Inspect buried horizontal fence material annually.
  • Page 12 Notes All Zoeller Pump Company products must be installed and maintained in accordance with all applicable codes. Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. © Copyright 2021. All rights reserved.